Alibaba's T-Head SoC Uncore Performance Monitoring Unit (PMU)
=============================================================
The Yitian 710, custom-built by Alibaba Group's chip development business,
T-Head, implements uncore PMU for performance and functional debugging to
facilitate system maintenance.
DDR Sub-System Driveway (DRW) PMU Driver
=========================================
Yitian 710 employs eight DDR5/4 channels, four on each die. Each DDR5 channel
is independent of others to service system memory requests. And one DDR5
channel is split into two independent sub-channels. The DDR Sub-System Driveway
implements separate PMUs for each sub-channel to monitor various performance
metrics.
The Driveway PMU devices are named as ali_drw_<sys_base_addr> with perf.
For example, ali_drw_21000 and ali_drw_21080 are two PMU devices for two
sub-channels of the same channel in die 0. And the PMU device of die 1 is
prefixed with ali_drw_400XXXXX, e.g. ali_drw_40021000.
Each sub-channel has 36 PMU counters in total, which is classified into
four groups:
- Group 0: PMU Cycle Counter. This group has one pair of counters
pmu_cycle_cnt_low and pmu_cycle_cnt_high, that is used as the cycle count
based on DDRC core clock.
- Group 1: PMU Bandwidth Counters. This group has 8 counters that are used
to count the total access number of either the eight bank groups in a
selected rank, or four ranks separately in the first 4 counters. The base
transfer unit is 64B.
- Group 2: PMU Retry Counters. This group has 10 counters, that intend to
count the total retry number of each type of uncorrectable error.
- Group 3: PMU Common Counters. This group has 16 counters, that are used
to count the common events.
For now, the Driveway PMU driver only uses counters in group 0 and group 3.
The DDR Controller (DDRCTL) and DDR PHY combine to create a complete solution
for connecting an SoC application bus to DDR memory devices. The DDRCTL
receives transactions Host Interface (HIF) which is custom-defined by Synopsys.
These transactions are queued internally and scheduled for access while
satisfying the SDRAM protocol timing requirements, transaction priorities, and
dependencies between the transactions. The DDRCTL in turn issues commands on
the DDR PHY Interface (DFI) to the PHY module, which launches and captures data
to and from the SDRAM. The driveway PMUs have hardware logic to gather
statistics and performance logging signals on HIF, DFI, etc.
By counting the READ, WRITE and RMW commands sent to the DDRC through the HIF
interface, we could calculate the bandwidth. Example usage of counting memory
data bandwidth::
perf stat \
-e ali_drw_21000/hif_wr/ \
-e ali_drw_21000/hif_rd/ \
-e ali_drw_21000/hif_rmw/ \
-e ali_drw_21000/cycle/ \
-e ali_drw_21080/hif_wr/ \
-e ali_drw_21080/hif_rd/ \
-e ali_drw_21080/hif_rmw/ \
-e ali_drw_21080/cycle/ \
-e ali_drw_23000/hif_wr/ \
-e ali_drw_23000/hif_rd/ \
-e ali_drw_23000/hif_rmw/ \
-e ali_drw_23000/cycle/ \
-e ali_drw_23080/hif_wr/ \
-e ali_drw_23080/hif_rd/ \
-e ali_drw_23080/hif_rmw/ \
-e ali_drw_23080/cycle/ \
-e ali_drw_25000/hif_wr/ \
-e ali_drw_25000/hif_rd/ \
-e ali_drw_25000/hif_rmw/ \
-e ali_drw_25000/cycle/ \
-e ali_drw_25080/hif_wr/ \
-e ali_drw_25080/hif_rd/ \
-e ali_drw_25080/hif_rmw/ \
-e ali_drw_25080/cycle/ \
-e ali_drw_27000/hif_wr/ \
-e ali_drw_27000/hif_rd/ \
-e ali_drw_27000/hif_rmw/ \
-e ali_drw_27000/cycle/ \
-e ali_drw_27080/hif_wr/ \
-e ali_drw_27080/hif_rd/ \
-e ali_drw_27080/hif_rmw/ \
-e ali_drw_27080/cycle/ -- sleep 10
Example usage of counting all memory read/write bandwidth by metric::
perf stat -M ddr_read_bandwidth.all -- sleep 10
perf stat -M ddr_write_bandwidth.all -- sleep 10
The average DRAM bandwidth can be calculated as follows:
- Read Bandwidth = perf_hif_rd * DDRC_WIDTH * DDRC_Freq / DDRC_Cycle
- Write Bandwidth = (perf_hif_wr + perf_hif_rmw) * DDRC_WIDTH * DDRC_Freq / DDRC_Cycle
Here, DDRC_WIDTH = 64 bytes.
The current driver does not support sampling. So "perf record" is
unsupported. Also attach to a task is unsupported as the events are all
uncore.
@@ -0,0 +1,29 @@
.. SPDX-License-Identifier: GPL-2.0
============================================
Ampere SoC Performance Monitoring Unit (PMU)
============================================
Ampere SoC PMU is a generic PMU IP that follows Arm CoreSight PMU architecture.
Therefore, the driver is implemented as a submodule of arm_cspmu driver. At the
first phase it's used for counting MCU events on AmpereOne.
MCU PMU events
--------------
The PMU driver supports setting filters for "rank", "bank", and "threshold".
Note, that the filters are per PMU instance rather than per event.
Example for perf tool use::
/ # perf list ampere
ampere_mcu_pmu_0/act_sent/ [Kernel PMU event]
<...>
ampere_mcu_pmu_1/rd_sent/ [Kernel PMU event]
<...>
/ # perf stat -a -e ampere_mcu_pmu_0/act_sent,bank=5,rank=3,threshold=2/,ampere_mcu_pmu_1/rd_sent/ \
sleep 1
@@ -0,0 +1,61 @@
==========================
ARM Cache Coherent Network
==========================
CCN-504 is a ring-bus interconnect consisting of 11 crosspoints
(XPs), with each crosspoint supporting up to two device ports,
so nodes (devices) 0 and 1 are connected to crosspoint 0,
nodes 2 and 3 to crosspoint 1 etc.
PMU (perf) driver
-----------------
The CCN driver registers a perf PMU driver, which provides
description of available events and configuration options
in sysfs, see /sys/bus/event_source/devices/ccn*.
The "format" directory describes format of the config, config1
and config2 fields of the perf_event_attr structure. The "events"
directory provides configuration templates for all documented
events, that can be used with perf tool. For example "xp_valid_flit"
is an equivalent of "type=0x8,event=0x4". Other parameters must be
explicitly specified.
For events originating from device, "node" defines its index.
Crosspoint PMU events require "xp" (index), "bus" (bus number)
and "vc" (virtual channel ID).
Crosspoint watchpoint-based events (special "event" value 0xfe)
require "xp" and "vc" as above plus "port" (device port index),
"dir" (transmit/receive direction), comparator values ("cmp_l"
and "cmp_h") and "mask", being index of the comparator mask.
Masks are defined separately from the event description
(due to limited number of the config values) in the "cmp_mask"
directory, with first 8 configurable by user and additional
4 hardcoded for the most frequent use cases.
Cycle counter is described by a "type" value 0xff and does
not require any other settings.
The driver also provides a "cpumask" sysfs attribute, which contains
a single CPU ID, of the processor which will be used to handle all
the CCN PMU events. It is recommended that the user space tools
request the events on this processor (if not, the perf_event->cpu value
will be overwritten anyway). In case of this processor being offlined,
the events are migrated to another one and the attribute is updated.
Example of perf tool use::
/ # perf list | grep ccn
ccn/cycles/ [Kernel PMU event]
<...>
ccn/xp_valid_flit,xp=?,port=?,vc=?,dir=?/ [Kernel PMU event]
<...>
/ # perf stat -a -e ccn/cycles/,ccn/xp_valid_flit,xp=1,port=0,vc=1,dir=1/ \
sleep 1
The driver does not support sampling, therefore "perf record" will
not work. Per-task (without "-a") perf sessions are not supported.
@@ -0,0 +1,65 @@
=============================
Arm Coherent Mesh Network PMU
=============================
CMN-600 is a configurable mesh interconnect consisting of a rectangular
grid of crosspoints (XPs), with each crosspoint supporting up to two
device ports to which various AMBA CHI agents are attached.
CMN implements a distributed PMU design as part of its debug and trace
functionality. This consists of a local monitor (DTM) at every XP, which
counts up to 4 event signals from the connected device nodes and/or the
XP itself. Overflow from these local counters is accumulated in up to 8
global counters implemented by the main controller (DTC), which provides
overall PMU control and interrupts for global counter overflow.
PMU events
----------
The PMU driver registers a single PMU device for the whole interconnect,
see /sys/bus/event_source/devices/arm_cmn_0. Multi-chip systems may link
more than one CMN together via external CCIX links - in this situation,
each mesh counts its own events entirely independently, and additional
PMU devices will be named arm_cmn_{1..n}.
Most events are specified in a format based directly on the TRM
definitions - "type" selects the respective node type, and "eventid" the
event number. Some events require an additional occupancy ID, which is
specified by "occupid".
* Since RN-D nodes do not have any distinct events from RN-I nodes, they
are treated as the same type (0xa), and the common event templates are
named "rnid_*".
* The cycle counter is treated as a synthetic event belonging to the DTC
node ("type" == 0x3, "eventid" is ignored).
* XP events also encode the port and channel in the "eventid" field, to
match the underlying pmu_event0_id encoding for the pmu_event_sel
register. The event templates are named with prefixes to cover all
permutations.
By default each event provides an aggregate count over all nodes of the
given type. To target a specific node, "bynodeid" must be set to 1 and
"nodeid" to the appropriate value derived from the CMN configuration
(as defined in the "Node ID Mapping" section of the TRM).
Watchpoints
-----------
The PMU can also count watchpoint events to monitor specific flit
traffic. Watchpoints are treated as a synthetic event type, and like PMU
events can be global or targeted with a particular XP's "nodeid" value.
Since the watchpoint direction is otherwise implicit in the underlying
register selection, separate events are provided for flit uploads and
downloads.
The flit match value and mask are passed in config1 and config2 ("val"
and "mask" respectively). "wp_dev_sel", "wp_chn_sel", "wp_grp" and
"wp_exclusive" are specified per the TRM definitions for dtm_wp_config0.
Where a watchpoint needs to match fields from both match groups on the
REQ or SNP channel, it can be specified as two events - one for each
group - with the same nonzero "combine" value. The count for such a
pair of combined events will be attributed to the primary match.
Watchpoint events with a "combine" value of 0 are considered independent
and will count individually.
@@ -0,0 +1,17 @@
====================================
Arm Network-on Chip Interconnect PMU
====================================
NI-700 and friends implement a distinct PMU for each clock domain within the
interconnect. Correspondingly, the driver exposes multiple PMU devices named
arm_ni_<x>_cd_<y>, where <x> is an (arbitrary) instance identifier and <y> is
the clock domain ID within that particular instance. If multiple NI instances
exist within a system, the PMU devices can be correlated with the underlying
hardware instance via sysfs parentage.
Each PMU exposes base event aliases for the interface types present in its clock
domain. These require qualifying with the "eventid" and "nodeid" parameters
to specify the event code to count and the interface at which to count it
(per the configured hardware ID as reflected in the xxNI_NODE_INFO register).
The exception is the "cycles" alias for the PMU cycle counter, which is encoded
with the PMU node type and needs no further qualification.
@@ -0,0 +1,29 @@
==================================
ARM DynamIQ Shared Unit (DSU) PMU
==================================
ARM DynamIQ Shared Unit integrates one or more cores with an L3 memory system,
control logic and external interfaces to form a multicore cluster. The PMU
allows counting the various events related to the L3 cache, Snoop Control Unit
etc, using 32bit independent counters. It also provides a 64bit cycle counter.
The PMU can only be accessed via CPU system registers and are common to the
cores connected to the same DSU. Like most of the other uncore PMUs, DSU
PMU doesn't support process specific events and cannot be used in sampling mode.
The DSU provides a bitmap for a subset of implemented events via hardware
registers. There is no way for the driver to determine if the other events
are available or not. Hence the driver exposes only those events advertised
by the DSU, in "events" directory under::
/sys/bus/event_sources/devices/arm_dsu_<N>/
The user should refer to the TRM of the product to figure out the supported events
and use the raw event code for the unlisted events.
The driver also exposes the CPUs connected to the DSU instance in "associated_cpus".
e.g usage::
perf stat -a -e arm_dsu_0/cycles/
@@ -0,0 +1,68 @@
.. SPDX-License-Identifier: GPL-2.0
======================================
CXL Performance Monitoring Unit (CPMU)
======================================
The CXL rev 3.0 specification provides a definition of CXL Performance
Monitoring Unit in section 13.2: Performance Monitoring.
CXL components (e.g. Root Port, Switch Upstream Port, End Point) may have
any number of CPMU instances. CPMU capabilities are fully discoverable from
the devices. The specification provides event definitions for all CXL protocol
message types and a set of additional events for things commonly counted on
CXL devices (e.g. DRAM events).
CPMU driver
===========
The CPMU driver registers a perf PMU with the name pmu_mem<X>.<Y> on the CXL bus
representing the Yth CPMU for memX.
/sys/bus/cxl/device/pmu_mem<X>.<Y>
The associated PMU is registered as
/sys/bus/event_sources/devices/cxl_pmu_mem<X>.<Y>
In common with other CXL bus devices, the id has no specific meaning and the
relationship to specific CXL device should be established via the device parent
of the device on the CXL bus.
PMU driver provides description of available events and filter options in sysfs.
The "format" directory describes all formats of the config (event vendor id,
group id and mask) config1 (threshold, filter enables) and config2 (filter
parameters) fields of the perf_event_attr structure. The "events" directory
describes all documented events show in perf list.
The events shown in perf list are the most fine grained events with a single
bit of the event mask set. More general events may be enable by setting
multiple mask bits in config. For example, all Device to Host Read Requests
may be captured on a single counter by setting the bits for all of
* d2h_req_rdcurr
* d2h_req_rdown
* d2h_req_rdshared
* d2h_req_rdany
* d2h_req_rdownnodata
Example of usage::
$#perf list
cxl_pmu_mem0.0/clock_ticks/ [Kernel PMU event]
cxl_pmu_mem0.0/d2h_req_rdshared/ [Kernel PMU event]
cxl_pmu_mem0.0/h2d_req_snpcur/ [Kernel PMU event]
cxl_pmu_mem0.0/h2d_req_snpdata/ [Kernel PMU event]
cxl_pmu_mem0.0/h2d_req_snpinv/ [Kernel PMU event]
-----------------------------------------------------------
$# perf stat -a -e cxl_pmu_mem0.0/clock_ticks/ -e cxl_pmu_mem0.0/d2h_req_rdshared/
Vendor specific events may also be available and if so can be used via
$# perf stat -a -e cxl_pmu_mem0.0/vid=VID,gid=GID,mask=MASK/
The driver does not support sampling so "perf record" is unsupported.
It only supports system-wide counting so attaching to a task is
unsupported.
@@ -0,0 +1,94 @@
======================================================================
Synopsys DesignWare Cores (DWC) PCIe Performance Monitoring Unit (PMU)
======================================================================
DesignWare Cores (DWC) PCIe PMU
===============================
The PMU is a PCIe configuration space register block provided by each PCIe Root
Port in a Vendor-Specific Extended Capability named RAS D.E.S (Debug, Error
injection, and Statistics).
As the name indicates, the RAS DES capability supports system level
debugging, AER error injection, and collection of statistics. To facilitate
collection of statistics, Synopsys DesignWare Cores PCIe controller
provides the following two features:
- one 64-bit counter for Time Based Analysis (RX/TX data throughput and
time spent in each low-power LTSSM state) and
- one 32-bit counter per event for Event Counting (error and non-error
events for a specified lane)
Note: There is no interrupt for counter overflow.
Time Based Analysis
-------------------
Using this feature you can obtain information regarding RX/TX data
throughput and time spent in each low-power LTSSM state by the controller.
The PMU measures data in two categories:
- Group#0: Percentage of time the controller stays in LTSSM states.
- Group#1: Amount of data processed (Units of 16 bytes).
Lane Event counters
-------------------
Using this feature you can obtain Error and Non-Error information in
specific lane by the controller. The PMU event is selected by all of:
- Group i
- Event j within the Group i
- Lane k
Some of the events only exist for specific configurations.
DesignWare Cores (DWC) PCIe PMU Driver
=======================================
This driver adds PMU devices for each PCIe Root Port named based on the SBDF of
the Root Port. For example,
0001:30:03.0 PCI bridge: Device 1ded:8000 (rev 01)
the PMU device name for this Root Port is dwc_rootport_13018.
The DWC PCIe PMU driver registers a perf PMU driver, which provides
description of available events and configuration options in sysfs, see
/sys/bus/event_source/devices/dwc_rootport_{sbdf}.
The "format" directory describes format of the config fields of the
perf_event_attr structure. The "events" directory provides configuration
templates for all documented events. For example,
"rx_pcie_tlp_data_payload" is an equivalent of "eventid=0x21,type=0x0".
The "perf list" command shall list the available events from sysfs, e.g.::
$# perf list | grep dwc_rootport
<...>
dwc_rootport_13018/Rx_PCIe_TLP_Data_Payload/ [Kernel PMU event]
<...>
dwc_rootport_13018/rx_memory_read,lane=?/ [Kernel PMU event]
Time Based Analysis Event Usage
-------------------------------
Example usage of counting PCIe RX TLP data payload (Units of bytes)::
$# perf stat -a -e dwc_rootport_13018/Rx_PCIe_TLP_Data_Payload/
The average RX/TX bandwidth can be calculated using the following formula:
PCIe RX Bandwidth = rx_pcie_tlp_data_payload / Measure_Time_Window
PCIe TX Bandwidth = tx_pcie_tlp_data_payload / Measure_Time_Window
Lane Event Usage
-------------------------------
Each lane has the same event set and to avoid generating a list of hundreds
of events, the user need to specify the lane ID explicitly, e.g.::
$# perf stat -a -e dwc_rootport_13018/rx_memory_read,lane=4/
The driver does not support sampling, therefore "perf record" will not
work. Per-task (without "-a") perf sessions are not supported.
@@ -0,0 +1,115 @@
.. SPDX-License-Identifier: GPL-2.0-only
================================================
Fujitsu Uncore Performance Monitoring Unit (PMU)
================================================
This driver supports the Uncore MAC PMUs and the Uncore PCI PMUs found
in Fujitsu chips.
Each MAC PMU on these chips is exposed as a uncore perf PMU with device name
mac_iod<iod>_mac<mac>_ch<ch>.
And each PCI PMU on these chips is exposed as a uncore perf PMU with device name
pci_iod<iod>_pci<pci>.
The driver provides a description of its available events and configuration
options in sysfs, see /sys/bus/event_sources/devices/mac_iod<iod>_mac<mac>_ch<ch>/
and /sys/bus/event_sources/devices/pci_iod<iod>_pci<pci>/.
This driver exports:
- formats, used by perf user space and other tools to configure events
- events, used by perf user space and other tools to create events
symbolically, e.g.::
perf stat -a -e mac_iod0_mac0_ch0/event=0x21/ ls
perf stat -a -e pci_iod0_pci0/event=0x24/ ls
- cpumask, used by perf user space and other tools to know on which CPUs
to open the events
This driver supports the following events for MAC:
- cycles
This event counts MAC cycles at MAC frequency.
- read-count
This event counts the number of read requests to MAC.
- read-count-request
This event counts the number of read requests including retry to MAC.
- read-count-return
This event counts the number of responses to read requests to MAC.
- read-count-request-pftgt
This event counts the number of read requests including retry with PFTGT
flag.
- read-count-request-normal
This event counts the number of read requests including retry without PFTGT
flag.
- read-count-return-pftgt-hit
This event counts the number of responses to read requests which hit the
PFTGT buffer.
- read-count-return-pftgt-miss
This event counts the number of responses to read requests which miss the
PFTGT buffer.
- read-wait
This event counts outstanding read requests issued by DDR memory controller
per cycle.
- write-count
This event counts the number of write requests to MAC (including zero write,
full write, partial write, write cancel).
- write-count-write
This event counts the number of full write requests to MAC (not including
zero write).
- write-count-pwrite
This event counts the number of partial write requests to MAC.
- memory-read-count
This event counts the number of read requests from MAC to memory.
- memory-write-count
This event counts the number of full write requests from MAC to memory.
- memory-pwrite-count
This event counts the number of partial write requests from MAC to memory.
- ea-mac
This event counts energy consumption of MAC.
- ea-memory
This event counts energy consumption of memory.
- ea-memory-mac-write
This event counts the number of write requests from MAC to memory.
- ea-ha
This event counts energy consumption of HA.
'ea' is the abbreviation for 'Energy Analyzer'.
Examples for use with perf::
perf stat -e mac_iod0_mac0_ch0/ea-mac/ ls
And, this driver supports the following events for PCI:
- pci-port0-cycles
This event counts PCI cycles at PCI frequency in port0.
- pci-port0-read-count
This event counts read transactions for data transfer in port0.
- pci-port0-read-count-bus
This event counts read transactions for bus usage in port0.
- pci-port0-write-count
This event counts write transactions for data transfer in port0.
- pci-port0-write-count-bus
This event counts write transactions for bus usage in port0.
- pci-port1-cycles
This event counts PCI cycles at PCI frequency in port1.
- pci-port1-read-count
This event counts read transactions for data transfer in port1.
- pci-port1-read-count-bus
This event counts read transactions for bus usage in port1.
- pci-port1-write-count
This event counts write transactions for data transfer in port1.
- pci-port1-write-count-bus
This event counts write transactions for bus usage in port1.
- ea-pci
This event counts energy consumption of PCI.
'ea' is the abbreviation for 'Energy Analyzer'.
Examples for use with perf::
perf stat -e pci_iod0_pci0/ea-pci/ ls
Given that these are uncore PMUs the driver does not support sampling, therefore
"perf record" will not work. Per-task perf sessions are not supported.
@@ -0,0 +1,148 @@
================================================
HiSilicon PCIe Performance Monitoring Unit (PMU)
================================================
On Hip09, HiSilicon PCIe Performance Monitoring Unit (PMU) could monitor
bandwidth, latency, bus utilization and buffer occupancy data of PCIe.
Each PCIe Core has a PMU to monitor multi Root Ports of this PCIe Core and
all Endpoints downstream these Root Ports.
HiSilicon PCIe PMU driver
=========================
The PCIe PMU driver registers a perf PMU with the name of its sicl-id and PCIe
Core id.::
/sys/bus/event_source/hisi_pcie<sicl>_core<core>
PMU driver provides description of available events and filter options in sysfs,
see /sys/bus/event_source/devices/hisi_pcie<sicl>_core<core>.
The "format" directory describes all formats of the config (events) and config1
(filter options) fields of the perf_event_attr structure. The "events" directory
describes all documented events shown in perf list.
The "identifier" sysfs file allows users to identify the version of the
PMU hardware device.
The "bus" sysfs file allows users to get the bus number of Root Ports
monitored by PMU. Furthermore users can get the Root Ports range in
[bdf_min, bdf_max] from "bdf_min" and "bdf_max" sysfs attributes
respectively.
Example usage of perf::
$# perf list
hisi_pcie0_core0/rx_mwr_latency/ [kernel PMU event]
hisi_pcie0_core0/rx_mwr_cnt/ [kernel PMU event]
------------------------------------------
$# perf stat -e hisi_pcie0_core0/rx_mwr_latency,port=0xffff/
$# perf stat -e hisi_pcie0_core0/rx_mwr_cnt,port=0xffff/
The related events usually used to calculate the bandwidth, latency or others.
They need to start and end counting at the same time, therefore related events
are best used in the same event group to get the expected value. There are two
ways to know if they are related events:
a) By event name, such as the latency events "xxx_latency, xxx_cnt" or
bandwidth events "xxx_flux, xxx_time".
b) By event type, such as "event=0xXXXX, event=0x1XXXX".
Example usage of perf group::
$# perf stat -e "{hisi_pcie0_core0/rx_mwr_latency,port=0xffff/,hisi_pcie0_core0/rx_mwr_cnt,port=0xffff/}"
The current driver does not support sampling. So "perf record" is unsupported.
Also attach to a task is unsupported for PCIe PMU.
Filter options
--------------
1. Target filter
PMU could only monitor the performance of traffic downstream target Root
Ports or downstream target Endpoint. PCIe PMU driver support "port" and
"bdf" interfaces for users.
Please notice that, one of these two interfaces must be set, and these two
interfaces aren't supported at the same time. If they are both set, only
"port" filter is valid.
If "port" filter not being set or is set explicitly to zero (default), the
"bdf" filter will be in effect, because "bdf=0" meaning 0000:000:00.0.
- port
"port" filter can be used in all PCIe PMU events, target Root Port can be
selected by configuring the 16-bits-bitmap "port". Multi ports can be
selected for AP-layer-events, and only one port can be selected for
TL/DL-layer-events.
For example, if target Root Port is 0000:00:00.0 (x8 lanes), bit0 of
bitmap should be set, port=0x1; if target Root Port is 0000:00:04.0 (x4
lanes), bit8 is set, port=0x100; if these two Root Ports are both
monitored, port=0x101.
Example usage of perf::
$# perf stat -e hisi_pcie0_core0/rx_mwr_latency,port=0x1/ sleep 5
- bdf
"bdf" filter can only be used in bandwidth events, target Endpoint is
selected by configuring BDF to "bdf". Counter only counts the bandwidth of
message requested by target Endpoint.
For example, "bdf=0x3900" means BDF of target Endpoint is 0000:39:00.0.
Example usage of perf::
$# perf stat -e hisi_pcie0_core0/rx_mrd_flux,bdf=0x3900/ sleep 5
2. Trigger filter
Event statistics start when the first time TLP length is greater/smaller
than trigger condition. You can set the trigger condition by writing
"trig_len", and set the trigger mode by writing "trig_mode". This filter can
only be used in bandwidth events.
For example, "trig_len=4" means trigger condition is 2^4 DW, "trig_mode=0"
means statistics start when TLP length > trigger condition, "trig_mode=1"
means start when TLP length < condition.
Example usage of perf::
$# perf stat -e hisi_pcie0_core0/rx_mrd_flux,port=0xffff,trig_len=0x4,trig_mode=1/ sleep 5
3. Threshold filter
Counter counts when TLP length within the specified range. You can set the
threshold by writing "thr_len", and set the threshold mode by writing
"thr_mode". This filter can only be used in bandwidth events.
For example, "thr_len=4" means threshold is 2^4 DW, "thr_mode=0" means
counter counts when TLP length >= threshold, and "thr_mode=1" means counts
when TLP length < threshold.
Example usage of perf::
$# perf stat -e hisi_pcie0_core0/rx_mrd_flux,port=0xffff,thr_len=0x4,thr_mode=1/ sleep 5
4. TLP Length filter
When counting bandwidth, the data can be composed of certain parts of TLP
packets. You can specify it through "len_mode":
- 2'b00: Reserved (Do not use this since the behaviour is undefined)
- 2'b01: Bandwidth of TLP payloads
- 2'b10: Bandwidth of TLP headers
- 2'b11: Bandwidth of both TLP payloads and headers
For example, "len_mode=2" means only counting the bandwidth of TLP headers
and "len_mode=3" means the final bandwidth data is composed of both TLP
headers and payloads. Default value if not specified is 2'b11.
Example usage of perf::
$# perf stat -e hisi_pcie0_core0/rx_mrd_flux,port=0xffff,len_mode=0x1/ sleep 5
@@ -0,0 +1,177 @@
======================================================
HiSilicon SoC uncore Performance Monitoring Unit (PMU)
======================================================
The HiSilicon SoC chip includes various independent system device PMUs
such as L3 cache (L3C), Hydra Home Agent (HHA) and DDRC. These PMUs are
independent and have hardware logic to gather statistics and performance
information.
The HiSilicon SoC encapsulates multiple CPU and IO dies. Each CPU cluster
(CCL) is made up of 4 cpu cores sharing one L3 cache; each CPU die is
called Super CPU cluster (SCCL) and is made up of 6 CCLs. Each SCCL has
two HHAs (0 - 1) and four DDRCs (0 - 3), respectively.
HiSilicon SoC uncore PMU driver
-------------------------------
Each device PMU has separate registers for event counting, control and
interrupt, and the PMU driver shall register perf PMU drivers like L3C,
HHA and DDRC etc. The available events and configuration options shall
be described in the sysfs, see::
/sys/bus/event_source/devices/hisi_sccl{X}_<l3c{Y}/hha{Y}/ddrc{Y}>
The "perf list" command shall list the available events from sysfs.
Each L3C, HHA and DDRC is registered as a separate PMU with perf. The PMU
name will appear in event listing as hisi_sccl<sccl-id>_module<index-id>.
where "sccl-id" is the identifier of the SCCL and "index-id" is the index of
module.
e.g. hisi_sccl3_l3c0/rd_hit_cpipe is READ_HIT_CPIPE event of L3C index #0 in
SCCL ID #3.
e.g. hisi_sccl1_hha0/rx_operations is RX_OPERATIONS event of HHA index #0 in
SCCL ID #1.
The driver also provides a "cpumask" sysfs attribute, which shows the CPU core
ID used to count the uncore PMU event. An "associated_cpus" sysfs attribute is
also provided to show the CPUs associated with this PMU. The "cpumask" indicates
the CPUs to open the events, usually as a hint for userspaces tools like perf.
It only contains one associated CPU from the "associated_cpus".
Example usage of perf::
$# perf list
hisi_sccl3_l3c0/rd_hit_cpipe/ [kernel PMU event]
------------------------------------------
hisi_sccl3_l3c0/wr_hit_cpipe/ [kernel PMU event]
------------------------------------------
hisi_sccl1_l3c0/rd_hit_cpipe/ [kernel PMU event]
------------------------------------------
hisi_sccl1_l3c0/wr_hit_cpipe/ [kernel PMU event]
------------------------------------------
$# perf stat -a -e hisi_sccl3_l3c0/rd_hit_cpipe/ sleep 5
$# perf stat -a -e hisi_sccl3_l3c0/config=0x02/ sleep 5
For HiSilicon uncore PMU v2 whose identifier is 0x30, the topology is the same
as PMU v1, but some new functions are added to the hardware.
1. L3C PMU supports filtering by core/thread within the cluster which can be
specified as a bitmap::
$# perf stat -a -e hisi_sccl3_l3c0/config=0x02,tt_core=0x3/ sleep 5
This will only count the operations from core/thread 0 and 1 in this cluster.
User should not use tt_core_deprecated to specify the core/thread filtering.
This option is provided for backward compatiblility and only support 8bit
which may not cover all the core/thread sharing L3C.
2. Tracetag allow the user to chose to count only read, write or atomic
operations via the tt_req parameeter in perf. The default value counts all
operations. tt_req is 3bits, 3'b100 represents read operations, 3'b101
represents write operations, 3'b110 represents atomic store operations and
3'b111 represents atomic non-store operations, other values are reserved::
$# perf stat -a -e hisi_sccl3_l3c0/config=0x02,tt_req=0x4/ sleep 5
This will only count the read operations in this cluster.
3. Datasrc allows the user to check where the data comes from. It is 5 bits.
Some important codes are as follows:
- 5'b00001: comes from L3C in this die;
- 5'b01000: comes from L3C in the cross-die;
- 5'b01001: comes from L3C which is in another socket;
- 5'b01110: comes from the local DDR;
- 5'b01111: comes from the cross-die DDR;
- 5'b10000: comes from cross-socket DDR;
etc, it is mainly helpful to find that the data source is nearest from the CPU
cores. If datasrc_cfg is used in the multi-chips, the datasrc_skt shall be
configured in perf command::
$# perf stat -a -e hisi_sccl3_l3c0/config=0xb9,datasrc_cfg=0xE/,
hisi_sccl3_l3c0/config=0xb9,datasrc_cfg=0xF/ sleep 5
4. Some HiSilicon SoCs encapsulate multiple CPU and IO dies. Each CPU die
contains several Compute Clusters (CCLs). The I/O dies are called Super I/O
clusters (SICL) containing multiple I/O clusters (ICLs). Each CCL/ICL in the
SoC has a unique ID. Each ID is 11bits, include a 6-bit SCCL-ID and 5-bit
CCL/ICL-ID. For I/O die, the ICL-ID is followed by:
- 5'b00000: I/O_MGMT_ICL;
- 5'b00001: Network_ICL;
- 5'b00011: HAC_ICL;
- 5'b10000: PCIe_ICL;
5. uring_channel: UC PMU events 0x47~0x59 supports filtering by tx request
uring channel. It is 2 bits. Some important codes are as follows:
- 2'b11: count the events which sent to the uring_ext (MATA) channel;
- 2'b01: is the same as 2'b11;
- 2'b10: count the events which sent to the uring (non-MATA) channel;
- 2'b00: default value, count the events which sent to both uring and
uring_ext channels;
6. ch: NoC PMU supports filtering the event counts of certain transaction
channel with this option. The current supported channels are as follows:
- 3'b010: Request channel
- 3'b100: Snoop channel
- 3'b110: Response channel
- 3'b111: Data channel
7. tt_en: NoC PMU supports counting only transactions that have tracetag set
if this option is set. See the 2nd list for more information about tracetag.
For HiSilicon uncore PMU v3 whose identifier is 0x40, some uncore PMUs are
further divided into parts for finer granularity of tracing, each part has its
own dedicated PMU, and all such PMUs together cover the monitoring job of events
on particular uncore device. Such PMUs are described in sysfs with name format
slightly changed::
/sys/bus/event_source/devices/hisi_sccl{X}_<l3c{Y}_{Z}/ddrc{Y}_{Z}/noc{Y}_{Z}>
Z is the sub-id, indicating different PMUs for part of hardware device.
Usage of most PMUs with different sub-ids are identical. Specially, L3C PMU
provides ``ext`` option to allow exploration of even finer granual statistics
of L3C PMU. L3C PMU driver uses that as hint of termination when delivering
perf command to hardware:
- ext=0: Default, could be used with event names.
- ext=1 and ext=2: Must be used with event codes, event names are not supported.
An example of perf command could be::
$# perf stat -a -e hisi_sccl0_l3c1_0/rd_spipe/ sleep 5
or::
$# perf stat -a -e hisi_sccl0_l3c1_0/event=0x1,ext=1/ sleep 5
As above, ``hisi_sccl0_l3c1_0`` locates PMU of Super CPU CLuster 0, L3 cache 1
pipe0.
First command locates the first part of L3C since ``ext=0`` is implied by
default. Second command issues the counting on another part of L3C with the
event ``0x1``.
Users could configure IDs to count data come from specific CCL/ICL, by setting
srcid_cmd & srcid_msk, and data desitined for specific CCL/ICL by setting
tgtid_cmd & tgtid_msk. A set bit in srcid_msk/tgtid_msk means the PMU will not
check the bit when matching against the srcid_cmd/tgtid_cmd.
If all of these options are disabled, it can works by the default value that
doesn't distinguish the filter condition and ID information and will return
the total counter values in the PMU counters.
The current driver does not support sampling. So "perf record" is unsupported.
Also attach to a task is unsupported as the events are all uncore.
Note: Please contact the maintainer for a complete list of events supported for
the PMU devices in the SoC and its information if needed.
@@ -0,0 +1,136 @@
======================================
HNS3 Performance Monitoring Unit (PMU)
======================================
HNS3(HiSilicon network system 3) Performance Monitoring Unit (PMU) is an
End Point device to collect performance statistics of HiSilicon SoC NIC.
On Hip09, each SICL(Super I/O cluster) has one PMU device.
HNS3 PMU supports collection of performance statistics such as bandwidth,
latency, packet rate and interrupt rate.
Each HNS3 PMU supports 8 hardware events.
HNS3 PMU driver
===============
The HNS3 PMU driver registers a perf PMU with the name of its sicl id.::
/sys/bus/event_source/devices/hns3_pmu_sicl_<sicl_id>
PMU driver provides description of available events, filter modes, format,
identifier and cpumask in sysfs.
The "events" directory describes the event code of all supported events
shown in perf list.
The "filtermode" directory describes the supported filter modes of each
event.
The "format" directory describes all formats of the config (events) and
config1 (filter options) fields of the perf_event_attr structure.
The "identifier" file shows version of PMU hardware device.
The "bdf_min" and "bdf_max" files show the supported bdf range of each
pmu device.
The "hw_clk_freq" file shows the hardware clock frequency of each pmu
device.
Example usage of checking event code and subevent code::
$# cat /sys/bus/event_source/devices/hns3_pmu_sicl_0/events/dly_tx_normal_to_mac_time
config=0x00204
$# cat /sys/bus/event_source/devices/hns3_pmu_sicl_0/events/dly_tx_normal_to_mac_packet_num
config=0x10204
Each performance statistic has a pair of events to get two values to
calculate real performance data in userspace.
The bits 0~15 of config (here 0x0204) are the true hardware event code. If
two events have same value of bits 0~15 of config, that means they are
event pair. And the bit 16 of config indicates getting counter 0 or
counter 1 of hardware event.
After getting two values of event pair in userspace, the formula of
computation to calculate real performance data is:::
counter 0 / counter 1
Example usage of checking supported filter mode::
$# cat /sys/bus/event_source/devices/hns3_pmu_sicl_0/filtermode/bw_ssu_rpu_byte_num
filter mode supported: global/port/port-tc/func/func-queue/
Example usage of perf::
$# perf list
hns3_pmu_sicl_0/bw_ssu_rpu_byte_num/ [kernel PMU event]
hns3_pmu_sicl_0/bw_ssu_rpu_time/ [kernel PMU event]
------------------------------------------
$# perf stat -g -e hns3_pmu_sicl_0/bw_ssu_rpu_byte_num,global=1/ -e hns3_pmu_sicl_0/bw_ssu_rpu_time,global=1/ -I 1000
or
$# perf stat -g -e hns3_pmu_sicl_0/config=0x00002,global=1/ -e hns3_pmu_sicl_0/config=0x10002,global=1/ -I 1000
Filter modes
--------------
1. global mode
PMU collect performance statistics for all HNS3 PCIe functions of IO DIE.
Set the "global" filter option to 1 will enable this mode.
Example usage of perf::
$# perf stat -a -e hns3_pmu_sicl_0/config=0x1020F,global=1/ -I 1000
2. port mode
PMU collect performance statistic of one whole physical port. The port id
is same as mac id. The "tc" filter option must be set to 0xF in this mode,
here tc stands for traffic class.
Example usage of perf::
$# perf stat -a -e hns3_pmu_sicl_0/config=0x1020F,port=0,tc=0xF/ -I 1000
3. port-tc mode
PMU collect performance statistic of one tc of physical port. The port id
is same as mac id. The "tc" filter option must be set to 0 ~ 7 in this
mode.
Example usage of perf::
$# perf stat -a -e hns3_pmu_sicl_0/config=0x1020F,port=0,tc=0/ -I 1000
4. func mode
PMU collect performance statistic of one PF/VF. The function id is BDF of
PF/VF, its conversion formula::
func = (bus << 8) + (device << 3) + (function)
for example:
BDF func
35:00.0 0x3500
35:00.1 0x3501
35:01.0 0x3508
In this mode, the "queue" filter option must be set to 0xFFFF.
Example usage of perf::
$# perf stat -a -e hns3_pmu_sicl_0/config=0x1020F,bdf=0x3500,queue=0xFFFF/ -I 1000
5. func-queue mode
PMU collect performance statistic of one queue of PF/VF. The function id
is BDF of PF/VF, the "queue" filter option must be set to the exact queue
id of function.
Example usage of perf::
$# perf stat -a -e hns3_pmu_sicl_0/config=0x1020F,bdf=0x3500,queue=0/ -I 1000
6. func-intr mode
PMU collect performance statistic of one interrupt of PF/VF. The function
id is BDF of PF/VF, the "intr" filter option must be set to the exact
interrupt id of function.
Example usage of perf::
$# perf stat -a -e hns3_pmu_sicl_0/config=0x00301,bdf=0x3500,intr=0/ -I 1000
@@ -0,0 +1,100 @@
=====================================================
Freescale i.MX8 DDR Performance Monitoring Unit (PMU)
=====================================================
There are no performance counters inside the DRAM controller, so performance
signals are brought out to the edge of the controller where a set of 4 x 32 bit
counters is implemented. This is controlled by the CSV modes programmed in counter
control register which causes a large number of PERF signals to be generated.
Selection of the value for each counter is done via the config registers. There
is one register for each counter. Counter 0 is special in that it always counts
“time” and when expired causes a lock on itself and the other counters and an
interrupt is raised. If any other counter overflows, it continues counting, and
no interrupt is raised.
The "format" directory describes format of the config (event ID) and config1/2
(AXI filter setting) fields of the perf_event_attr structure, see /sys/bus/event_source/
devices/imx8_ddr0/format/. The "events" directory describes the events types
hardware supported that can be used with perf tool, see /sys/bus/event_source/
devices/imx8_ddr0/events/. The "caps" directory describes filter features implemented
in DDR PMU, see /sys/bus/events_source/devices/imx8_ddr0/caps/.
.. code-block:: bash
perf stat -a -e imx8_ddr0/cycles/ cmd
perf stat -a -e imx8_ddr0/read/,imx8_ddr0/write/ cmd
AXI filtering is only used by CSV modes 0x41 (axid-read) and 0x42 (axid-write)
to count reading or writing matches filter setting. Filter setting is various
from different DRAM controller implementations, which is distinguished by quirks
in the driver. You also can dump info from userspace, "caps" directory show the
type of AXI filter (filter, enhanced_filter and super_filter). Value 0 for
un-supported, and value 1 for supported.
* With DDR_CAP_AXI_ID_FILTER quirk(filter: 1, enhanced_filter: 0, super_filter: 0).
Filter is defined with two configuration parts:
--AXI_ID defines AxID matching value.
--AXI_MASKING defines which bits of AxID are meaningful for the matching.
- 0: corresponding bit is masked.
- 1: corresponding bit is not masked, i.e. used to do the matching.
AXI_ID and AXI_MASKING are mapped on DPCR1 register in performance counter.
When non-masked bits are matching corresponding AXI_ID bits then counter is
incremented. Perf counter is incremented if::
AxID && AXI_MASKING == AXI_ID && AXI_MASKING
This filter doesn't support filter different AXI ID for axid-read and axid-write
event at the same time as this filter is shared between counters.
.. code-block:: bash
perf stat -a -e imx8_ddr0/axid-read,axi_mask=0xMMMM,axi_id=0xDDDD/ cmd
perf stat -a -e imx8_ddr0/axid-write,axi_mask=0xMMMM,axi_id=0xDDDD/ cmd
.. note::
axi_mask is inverted in userspace(i.e. set bits are bits to mask), and
it will be reverted in driver automatically. so that the user can just specify
axi_id to monitor a specific id, rather than having to specify axi_mask.
.. code-block:: bash
perf stat -a -e imx8_ddr0/axid-read,axi_id=0x12/ cmd, which will monitor ARID=0x12
* With DDR_CAP_AXI_ID_FILTER_ENHANCED quirk(filter: 1, enhanced_filter: 1, super_filter: 0).
This is an extension to the DDR_CAP_AXI_ID_FILTER quirk which permits
counting the number of bytes (as opposed to the number of bursts) from DDR
read and write transactions concurrently with another set of data counters.
* With DDR_CAP_AXI_ID_PORT_CHANNEL_FILTER quirk(filter: 0, enhanced_filter: 0, super_filter: 1).
There is a limitation in previous AXI filter, it cannot filter different IDs
at the same time as the filter is shared between counters. This quirk is the
extension of AXI ID filter. One improvement is that counter 1-3 has their own
filter, means that it supports concurrently filter various IDs. Another
improvement is that counter 1-3 supports AXI PORT and CHANNEL selection. Support
selecting address channel or data channel.
Filter is defined with 2 configuration registers per counter 1-3.
--Counter N MASK COMP register - including AXI_ID and AXI_MASKING.
--Counter N MUX CNTL register - including AXI CHANNEL and AXI PORT.
- 0: address channel
- 1: data channel
PMU in DDR subsystem, only one single port0 exists, so axi_port is reserved
which should be 0.
.. code-block:: bash
perf stat -a -e imx8_ddr0/axid-read,axi_mask=0xMMMM,axi_id=0xDDDD,axi_channel=0xH/ cmd
perf stat -a -e imx8_ddr0/axid-write,axi_mask=0xMMMM,axi_id=0xDDDD,axi_channel=0xH/ cmd
.. note::
axi_channel is inverted in userspace, and it will be reverted in driver
automatically. So that users do not need specify axi_channel if want to
monitor data channel from DDR transactions, since data channel is more
meaningful.
@@ -0,0 +1,33 @@
.. SPDX-License-Identifier: GPL-2.0
===========================
Performance monitor support
===========================
.. toctree::
:maxdepth: 1
hisi-pmu
hisi-pcie-pmu
hns3-pmu
imx-ddr
qcom_l2_pmu
qcom_l3_pmu
starfive_starlink_pmu
mrvl-odyssey-ddr-pmu
mrvl-odyssey-tad-pmu
arm-ccn
arm-cmn
arm-ni
xgene-pmu
arm_dsu_pmu
thunderx2-pmu
alibaba_pmu
dwc_pcie_pmu
nvidia-tegra241-pmu
nvidia-tegra410-pmu
meson-ddr-pmu
cxl
ampere_cspmu
mrvl-pem-pmu
fujitsu_uncore_pmu
@@ -0,0 +1,70 @@
.. SPDX-License-Identifier: GPL-2.0
===========================================================
Amlogic SoC DDR Bandwidth Performance Monitoring Unit (PMU)
===========================================================
The Amlogic Meson G12 SoC contains a bandwidth monitor inside DRAM controller.
The monitor includes 4 channels. Each channel can count the request accessing
DRAM. The channel can count up to 3 AXI port simultaneously. It can be helpful
to show if the performance bottleneck is on DDR bandwidth.
Currently, this driver supports the following 5 perf events:
+ meson_ddr_bw/total_rw_bytes/
+ meson_ddr_bw/chan_1_rw_bytes/
+ meson_ddr_bw/chan_2_rw_bytes/
+ meson_ddr_bw/chan_3_rw_bytes/
+ meson_ddr_bw/chan_4_rw_bytes/
meson_ddr_bw/chan_{1,2,3,4}_rw_bytes/ events are channel-specific events.
Each channel support filtering, which can let the channel to monitor
individual IP module in SoC.
Below are DDR access request event filter keywords:
+ arm - from CPU
+ vpu_read1 - from OSD + VPP read
+ gpu - from 3D GPU
+ pcie - from PCIe controller
+ hdcp - from HDCP controller
+ hevc_front - from HEVC codec front end
+ usb3_0 - from USB3.0 controller
+ hevc_back - from HEVC codec back end
+ h265enc - from HEVC encoder
+ vpu_read2 - from DI read
+ vpu_write1 - from VDIN write
+ vpu_write2 - from di write
+ vdec - from legacy codec video decoder
+ hcodec - from H264 encoder
+ ge2d - from ge2d
+ spicc1 - from SPI controller 1
+ usb0 - from USB2.0 controller 0
+ dma - from system DMA controller 1
+ arb0 - from arb0
+ sd_emmc_b - from SD eMMC b controller
+ usb1 - from USB2.0 controller 1
+ audio - from Audio module
+ sd_emmc_c - from SD eMMC c controller
+ spicc2 - from SPI controller 2
+ ethernet - from Ethernet controller
Examples:
+ Show the total DDR bandwidth per seconds:
.. code-block:: bash
perf stat -a -e meson_ddr_bw/total_rw_bytes/ -I 1000 sleep 10
+ Show individual DDR bandwidth from CPU and GPU respectively, as well as
sum of them:
.. code-block:: bash
perf stat -a -e meson_ddr_bw/chan_1_rw_bytes,arm=1/ -I 1000 sleep 10
perf stat -a -e meson_ddr_bw/chan_2_rw_bytes,gpu=1/ -I 1000 sleep 10
perf stat -a -e meson_ddr_bw/chan_3_rw_bytes,arm=1,gpu=1/ -I 1000 sleep 10
@@ -0,0 +1,80 @@
===================================================================
Marvell Odyssey DDR PMU Performance Monitoring Unit (PMU UNCORE)
===================================================================
Odyssey DRAM Subsystem supports eight counters for monitoring performance
and software can program those counters to monitor any of the defined
performance events. Supported performance events include those counted
at the interface between the DDR controller and the PHY, interface between
the DDR Controller and the CHI interconnect, or within the DDR Controller.
Additionally DSS also supports two fixed performance event counters, one
for ddr reads and the other for ddr writes.
The counter will be operating in either manual or auto mode.
The PMU driver exposes the available events and format options under sysfs::
/sys/bus/event_source/devices/mrvl_ddr_pmu_<>/events/
/sys/bus/event_source/devices/mrvl_ddr_pmu_<>/format/
Examples::
$ perf list | grep ddr
mrvl_ddr_pmu_<>/ddr_act_bypass_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_bsm_alloc/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_bsm_starvation/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_cam_active_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_cam_mwr/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_cam_rd_active_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_cam_rd_or_wr_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_cam_read/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_cam_wr_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_cam_write/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_capar_error/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_crit_ref/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_ddr_reads/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_ddr_writes/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_dfi_cmd_is_retry/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_dfi_cycles/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_dfi_parity_poison/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_dfi_rd_data_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_dfi_wr_data_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_dqsosc_mpc/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_dqsosc_mrr/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_enter_mpsm/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_enter_powerdown/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_enter_selfref/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_hif_pri_rdaccess/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_hif_rd_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_hif_rd_or_wr_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_hif_rmw_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_hif_wr_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_hpri_sched_rd_crit_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_load_mode/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_lpri_sched_rd_crit_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_precharge/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_precharge_for_other/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_precharge_for_rdwr/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_raw_hazard/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_rd_bypass_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_rd_crc_error/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_rd_uc_ecc_error/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_rdwr_transitions/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_refresh/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_retry_fifo_full/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_spec_ref/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_tcr_mrr/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_war_hazard/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_waw_hazard/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_win_limit_reached_rd/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_win_limit_reached_wr/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_wr_crc_error/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_wr_trxn_crit_access/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_write_combine/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_zqcl/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_zqlatch/ [Kernel PMU event]
mrvl_ddr_pmu_<>/ddr_zqstart/ [Kernel PMU event]
$ perf stat -e ddr_cam_read,ddr_cam_write,ddr_cam_active_access,ddr_cam
rd_or_wr_access,ddr_cam_rd_active_access,ddr_cam_mwr <workload>
@@ -0,0 +1,37 @@
====================================================================
Marvell Odyssey LLC-TAD Performance Monitoring Unit (PMU UNCORE)
====================================================================
Each TAD provides eight 64-bit counters for monitoring
cache behavior.The driver always configures the same counter for
all the TADs. The user would end up effectively reserving one of
eight counters in every TAD to look across all TADs.
The occurrences of events are aggregated and presented to the user
at the end of running the workload. The driver does not provide a
way for the user to partition TADs so that different TADs are used for
different applications.
The performance events reflect various internal or interface activities.
By combining the values from multiple performance counters, cache
performance can be measured in terms such as: cache miss rate, cache
allocations, interface retry rate, internal resource occupancy, etc.
The PMU driver exposes the available events and format options under sysfs::
/sys/bus/event_source/devices/tad/events/
/sys/bus/event_source/devices/tad/format/
Examples::
$ perf list | grep tad
tad/tad_alloc_any/ [Kernel PMU event]
tad/tad_alloc_dtg/ [Kernel PMU event]
tad/tad_alloc_ltg/ [Kernel PMU event]
tad/tad_hit_any/ [Kernel PMU event]
tad/tad_hit_dtg/ [Kernel PMU event]
tad/tad_hit_ltg/ [Kernel PMU event]
tad/tad_req_msh_in_exlmn/ [Kernel PMU event]
tad/tad_tag_rd/ [Kernel PMU event]
tad/tad_tot_cycle/ [Kernel PMU event]
$ perf stat -e tad_alloc_dtg,tad_alloc_ltg,tad_alloc_any,tad_hit_dtg,tad_hit_ltg,tad_hit_any,tad_tag_rd <workload>
@@ -0,0 +1,56 @@
=================================================================
Marvell Odyssey PEM Performance Monitoring Unit (PMU UNCORE)
=================================================================
The PCI Express Interface Units(PEM) are associated with a corresponding
monitoring unit. This includes performance counters to track various
characteristics of the data that is transmitted over the PCIe link.
The counters track inbound and outbound transactions which
includes separate counters for posted/non-posted/completion TLPs.
Also, inbound and outbound memory read requests along with their
latencies can also be monitored. Address Translation Services(ATS)events
such as ATS Translation, ATS Page Request, ATS Invalidation along with
their corresponding latencies are also tracked.
There are separate 64 bit counters to measure posted/non-posted/completion
tlps in inbound and outbound transactions. ATS events are measured by
different counters.
The PMU driver exposes the available events and format options under sysfs,
/sys/bus/event_source/devices/mrvl_pcie_rc_pmu_<>/events/
/sys/bus/event_source/devices/mrvl_pcie_rc_pmu_<>/format/
Examples::
# perf list | grep mrvl_pcie_rc_pmu
mrvl_pcie_rc_pmu_<>/ats_inv/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ats_inv_latency/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ats_pri/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ats_pri_latency/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ats_trans/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ats_trans_latency/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ib_inflight/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ib_reads/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ib_req_no_ro_ebus/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ib_req_no_ro_ncb/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ib_tlp_cpl_partid/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ib_tlp_dwords_cpl_partid/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ib_tlp_dwords_npr/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ib_tlp_dwords_pr/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ib_tlp_npr/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ib_tlp_pr/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ob_inflight_partid/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ob_merges_cpl_partid/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ob_merges_npr_partid/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ob_merges_pr_partid/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ob_reads_partid/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ob_tlp_cpl_partid/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ob_tlp_dwords_cpl_partid/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ob_tlp_dwords_npr_partid/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ob_tlp_dwords_pr_partid/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ob_tlp_npr_partid/ [Kernel PMU event]
mrvl_pcie_rc_pmu_<>/ob_tlp_pr_partid/ [Kernel PMU event]
# perf stat -e ib_inflight,ib_reads,ib_req_no_ro_ebus,ib_req_no_ro_ncb <workload>
@@ -0,0 +1,333 @@
============================================================
NVIDIA Tegra241 SoC Uncore Performance Monitoring Unit (PMU)
============================================================
The NVIDIA Tegra241 SoC includes various system PMUs to measure key performance
metrics like memory bandwidth, latency, and utilization:
* Scalable Coherency Fabric (SCF)
* NVLink-C2C0
* NVLink-C2C1
* CNVLink
* PCIE
PMU Driver
----------
The PMUs in this document are based on ARM CoreSight PMU Architecture as
described in document: ARM IHI 0091. Since this is a standard architecture, the
PMUs are managed by a common driver "arm-cs-arch-pmu". This driver describes
the available events and configuration of each PMU in sysfs. Please see the
sections below to get the sysfs path of each PMU. Like other uncore PMU drivers,
the driver provides "cpumask" sysfs attribute to show the CPU id used to handle
the PMU event. There is also "associated_cpus" sysfs attribute, which contains a
list of CPUs associated with the PMU instance.
.. _SCF_PMU_Section:
SCF PMU
-------
The SCF PMU monitors system level cache events, CPU traffic, and
strongly-ordered (SO) PCIE write traffic to local/remote memory. Please see
:ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section` for more info about the PMU
traffic coverage.
The events and configuration options of this PMU device are described in sysfs,
see /sys/bus/event_source/devices/nvidia_scf_pmu_<socket-id>.
Example usage:
* Count event id 0x0 in socket 0::
perf stat -a -e nvidia_scf_pmu_0/event=0x0/
* Count event id 0x0 in socket 1::
perf stat -a -e nvidia_scf_pmu_1/event=0x0/
NVLink-C2C0 PMU
--------------------
The NVLink-C2C0 PMU monitors incoming traffic from a GPU/CPU connected with
NVLink-C2C (Chip-2-Chip) interconnect. The type of traffic captured by this PMU
varies dependent on the chip configuration:
* NVIDIA Grace Hopper Superchip: Hopper GPU is connected with Grace SoC.
In this config, the PMU captures GPU ATS translated or EGM traffic from the GPU.
* NVIDIA Grace CPU Superchip: two Grace CPU SoCs are connected.
In this config, the PMU captures read and relaxed ordered (RO) writes from
PCIE device of the remote SoC.
Please see :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section` for more info about
the PMU traffic coverage.
The events and configuration options of this PMU device are described in sysfs,
see /sys/bus/event_source/devices/nvidia_nvlink_c2c0_pmu_<socket-id>.
Example usage:
* Count event id 0x0 from the GPU/CPU connected with socket 0::
perf stat -a -e nvidia_nvlink_c2c0_pmu_0/event=0x0/
* Count event id 0x0 from the GPU/CPU connected with socket 1::
perf stat -a -e nvidia_nvlink_c2c0_pmu_1/event=0x0/
* Count event id 0x0 from the GPU/CPU connected with socket 2::
perf stat -a -e nvidia_nvlink_c2c0_pmu_2/event=0x0/
* Count event id 0x0 from the GPU/CPU connected with socket 3::
perf stat -a -e nvidia_nvlink_c2c0_pmu_3/event=0x0/
The NVLink-C2C has two ports that can be connected to one GPU (occupying both
ports) or to two GPUs (one GPU per port). The user can use "port" bitmap
parameter to select the port(s) to monitor. Each bit represents the port number,
e.g. "port=0x1" corresponds to port 0 and "port=0x3" is for port 0 and 1. The
PMU will monitor both ports by default if not specified.
Example for port filtering:
* Count event id 0x0 from the GPU connected with socket 0 on port 0::
perf stat -a -e nvidia_nvlink_c2c0_pmu_0/event=0x0,port=0x1/
* Count event id 0x0 from the GPUs connected with socket 0 on port 0 and port 1::
perf stat -a -e nvidia_nvlink_c2c0_pmu_0/event=0x0,port=0x3/
NVLink-C2C1 PMU
-------------------
The NVLink-C2C1 PMU monitors incoming traffic from a GPU connected with
NVLink-C2C (Chip-2-Chip) interconnect. This PMU captures untranslated GPU
traffic, in contrast with NvLink-C2C0 PMU that captures ATS translated traffic.
Please see :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section` for more info about
the PMU traffic coverage.
The events and configuration options of this PMU device are described in sysfs,
see /sys/bus/event_source/devices/nvidia_nvlink_c2c1_pmu_<socket-id>.
Example usage:
* Count event id 0x0 from the GPU connected with socket 0::
perf stat -a -e nvidia_nvlink_c2c1_pmu_0/event=0x0/
* Count event id 0x0 from the GPU connected with socket 1::
perf stat -a -e nvidia_nvlink_c2c1_pmu_1/event=0x0/
* Count event id 0x0 from the GPU connected with socket 2::
perf stat -a -e nvidia_nvlink_c2c1_pmu_2/event=0x0/
* Count event id 0x0 from the GPU connected with socket 3::
perf stat -a -e nvidia_nvlink_c2c1_pmu_3/event=0x0/
The NVLink-C2C has two ports that can be connected to one GPU (occupying both
ports) or to two GPUs (one GPU per port). The user can use "port" bitmap
parameter to select the port(s) to monitor. Each bit represents the port number,
e.g. "port=0x1" corresponds to port 0 and "port=0x3" is for port 0 and 1. The
PMU will monitor both ports by default if not specified.
Example for port filtering:
* Count event id 0x0 from the GPU connected with socket 0 on port 0::
perf stat -a -e nvidia_nvlink_c2c1_pmu_0/event=0x0,port=0x1/
* Count event id 0x0 from the GPUs connected with socket 0 on port 0 and port 1::
perf stat -a -e nvidia_nvlink_c2c1_pmu_0/event=0x0,port=0x3/
CNVLink PMU
---------------
The CNVLink PMU monitors traffic from GPU and PCIE device on remote sockets
to local memory. For PCIE traffic, this PMU captures read and relaxed ordered
(RO) write traffic. Please see :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section`
for more info about the PMU traffic coverage.
The events and configuration options of this PMU device are described in sysfs,
see /sys/bus/event_source/devices/nvidia_cnvlink_pmu_<socket-id>.
Each SoC socket can be connected to one or more sockets via CNVLink. The user can
use "rem_socket" bitmap parameter to select the remote socket(s) to monitor.
Each bit represents the socket number, e.g. "rem_socket=0xE" corresponds to
socket 1 to 3. The PMU will monitor all remote sockets by default if not
specified.
/sys/bus/event_source/devices/nvidia_cnvlink_pmu_<socket-id>/format/rem_socket
shows the valid bits that can be set in the "rem_socket" parameter.
The PMU can not distinguish the remote traffic initiator, therefore it does not
provide filter to select the traffic source to monitor. It reports combined
traffic from remote GPU and PCIE devices.
Example usage:
* Count event id 0x0 for the traffic from remote socket 1, 2, and 3 to socket 0::
perf stat -a -e nvidia_cnvlink_pmu_0/event=0x0,rem_socket=0xE/
* Count event id 0x0 for the traffic from remote socket 0, 2, and 3 to socket 1::
perf stat -a -e nvidia_cnvlink_pmu_1/event=0x0,rem_socket=0xD/
* Count event id 0x0 for the traffic from remote socket 0, 1, and 3 to socket 2::
perf stat -a -e nvidia_cnvlink_pmu_2/event=0x0,rem_socket=0xB/
* Count event id 0x0 for the traffic from remote socket 0, 1, and 2 to socket 3::
perf stat -a -e nvidia_cnvlink_pmu_3/event=0x0,rem_socket=0x7/
PCIE PMU
------------
The PCIE PMU monitors all read/write traffic from PCIE root ports to
local/remote memory. Please see :ref:`NVIDIA_Uncore_PMU_Traffic_Coverage_Section`
for more info about the PMU traffic coverage.
The events and configuration options of this PMU device are described in sysfs,
see /sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>.
Each SoC socket can support multiple root ports. The user can use
"root_port" bitmap parameter to select the port(s) to monitor, i.e.
"root_port=0xF" corresponds to root port 0 to 3. The PMU will monitor all root
ports by default if not specified.
/sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>/format/root_port
shows the valid bits that can be set in the "root_port" parameter.
Example usage:
* Count event id 0x0 from root port 0 and 1 of socket 0::
perf stat -a -e nvidia_pcie_pmu_0/event=0x0,root_port=0x3/
* Count event id 0x0 from root port 0 and 1 of socket 1::
perf stat -a -e nvidia_pcie_pmu_1/event=0x0,root_port=0x3/
.. _NVIDIA_Uncore_PMU_Traffic_Coverage_Section:
Traffic Coverage
----------------
The PMU traffic coverage may vary dependent on the chip configuration:
* **NVIDIA Grace Hopper Superchip**: Hopper GPU is connected with Grace SoC.
Example configuration with two Grace SoCs::
********************************* *********************************
* SOCKET-A * * SOCKET-B *
* * * *
* :::::::: * * :::::::: *
* : PCIE : * * : PCIE : *
* :::::::: * * :::::::: *
* | * * | *
* | * * | *
* ::::::: ::::::::: * * ::::::::: ::::::: *
* : : : : * * : : : : *
* : GPU :<--NVLink-->: Grace :<---CNVLink--->: Grace :<--NVLink-->: GPU : *
* : : C2C : SoC : * * : SoC : C2C : : *
* ::::::: ::::::::: * * ::::::::: ::::::: *
* | | * * | | *
* | | * * | | *
* &&&&&&&& &&&&&&&& * * &&&&&&&& &&&&&&&& *
* & GMEM & & CMEM & * * & CMEM & & GMEM & *
* &&&&&&&& &&&&&&&& * * &&&&&&&& &&&&&&&& *
* * * *
********************************* *********************************
GMEM = GPU Memory (e.g. HBM)
CMEM = CPU Memory (e.g. LPDDR5X)
|
| Following table contains traffic coverage of Grace SoC PMU in socket-A:
::
+--------------+-------+-----------+-----------+-----+----------+----------+
| | Source |
+ +-------+-----------+-----------+-----+----------+----------+
| Destination | |GPU ATS |GPU Not-ATS| | Socket-B | Socket-B |
| |PCI R/W|Translated,|Translated | CPU | CPU/PCIE1| GPU/PCIE2|
| | |EGM | | | | |
+==============+=======+===========+===========+=====+==========+==========+
| Local | PCIE |NVLink-C2C0|NVLink-C2C1| SCF | SCF PMU | CNVLink |
| SYSRAM/CMEM | PMU |PMU |PMU | PMU | | PMU |
+--------------+-------+-----------+-----------+-----+----------+----------+
| Local GMEM | PCIE | N/A |NVLink-C2C1| SCF | SCF PMU | CNVLink |
| | PMU | |PMU | PMU | | PMU |
+--------------+-------+-----------+-----------+-----+----------+----------+
| Remote | PCIE |NVLink-C2C0|NVLink-C2C1| SCF | | |
| SYSRAM/CMEM | PMU |PMU |PMU | PMU | N/A | N/A |
| over CNVLink | | | | | | |
+--------------+-------+-----------+-----------+-----+----------+----------+
| Remote GMEM | PCIE |NVLink-C2C0|NVLink-C2C1| SCF | | |
| over CNVLink | PMU |PMU |PMU | PMU | N/A | N/A |
+--------------+-------+-----------+-----------+-----+----------+----------+
PCIE1 traffic represents strongly ordered (SO) writes.
PCIE2 traffic represents reads and relaxed ordered (RO) writes.
* **NVIDIA Grace CPU Superchip**: two Grace CPU SoCs are connected.
Example configuration with two Grace SoCs::
******************* *******************
* SOCKET-A * * SOCKET-B *
* * * *
* :::::::: * * :::::::: *
* : PCIE : * * : PCIE : *
* :::::::: * * :::::::: *
* | * * | *
* | * * | *
* ::::::::: * * ::::::::: *
* : : * * : : *
* : Grace :<--------NVLink------->: Grace : *
* : SoC : * C2C * : SoC : *
* ::::::::: * * ::::::::: *
* | * * | *
* | * * | *
* &&&&&&&& * * &&&&&&&& *
* & CMEM & * * & CMEM & *
* &&&&&&&& * * &&&&&&&& *
* * * *
******************* *******************
GMEM = GPU Memory (e.g. HBM)
CMEM = CPU Memory (e.g. LPDDR5X)
|
| Following table contains traffic coverage of Grace SoC PMU in socket-A:
::
+-----------------+-----------+---------+----------+-------------+
| | Source |
+ +-----------+---------+----------+-------------+
| Destination | | | Socket-B | Socket-B |
| | PCI R/W | CPU | CPU/PCIE1| PCIE2 |
| | | | | |
+=================+===========+=========+==========+=============+
| Local | PCIE PMU | SCF PMU | SCF PMU | NVLink-C2C0 |
| SYSRAM/CMEM | | | | PMU |
+-----------------+-----------+---------+----------+-------------+
| Remote | | | | |
| SYSRAM/CMEM | PCIE PMU | SCF PMU | N/A | N/A |
| over NVLink-C2C | | | | |
+-----------------+-----------+---------+----------+-------------+
PCIE1 traffic represents strongly ordered (SO) writes.
PCIE2 traffic represents reads and relaxed ordered (RO) writes.
@@ -0,0 +1,522 @@
=====================================================================
NVIDIA Tegra410 SoC Uncore Performance Monitoring Unit (PMU)
=====================================================================
The NVIDIA Tegra410 SoC includes various system PMUs to measure key performance
metrics like memory bandwidth, latency, and utilization:
* Unified Coherence Fabric (UCF)
* PCIE
* PCIE-TGT
* CPU Memory (CMEM) Latency
* NVLink-C2C
* NV-CLink
* NV-DLink
PMU Driver
----------
The PMU driver describes the available events and configuration of each PMU in
sysfs. Please see the sections below to get the sysfs path of each PMU. Like
other uncore PMU drivers, the driver provides "cpumask" sysfs attribute to show
the CPU id used to handle the PMU event. There is also "associated_cpus"
sysfs attribute, which contains a list of CPUs associated with the PMU instance.
UCF PMU
-------
The Unified Coherence Fabric (UCF) in the NVIDIA Tegra410 SoC serves as a
distributed cache, last level for CPU Memory and CXL Memory, and cache coherent
interconnect that supports hardware coherence across multiple coherently caching
agents, including:
* CPU clusters
* GPU
* PCIe Ordering Controller Unit (OCU)
* Other IO-coherent requesters
The events and configuration options of this PMU device are described in sysfs,
see /sys/bus/event_source/devices/nvidia_ucf_pmu_<socket-id>.
Some of the events available in this PMU can be used to measure bandwidth and
utilization:
* slc_access_rd: count the number of read requests to SLC.
* slc_access_wr: count the number of write requests to SLC.
* slc_bytes_rd: count the number of bytes transferred by slc_access_rd.
* slc_bytes_wr: count the number of bytes transferred by slc_access_wr.
* mem_access_rd: count the number of read requests to local or remote memory.
* mem_access_wr: count the number of write requests to local or remote memory.
* mem_bytes_rd: count the number of bytes transferred by mem_access_rd.
* mem_bytes_wr: count the number of bytes transferred by mem_access_wr.
* cycles: counts the UCF cycles.
The average bandwidth is calculated as::
AVG_SLC_READ_BANDWIDTH_IN_GBPS = SLC_BYTES_RD / ELAPSED_TIME_IN_NS
AVG_SLC_WRITE_BANDWIDTH_IN_GBPS = SLC_BYTES_WR / ELAPSED_TIME_IN_NS
AVG_MEM_READ_BANDWIDTH_IN_GBPS = MEM_BYTES_RD / ELAPSED_TIME_IN_NS
AVG_MEM_WRITE_BANDWIDTH_IN_GBPS = MEM_BYTES_WR / ELAPSED_TIME_IN_NS
The average request rate is calculated as::
AVG_SLC_READ_REQUEST_RATE = SLC_ACCESS_RD / CYCLES
AVG_SLC_WRITE_REQUEST_RATE = SLC_ACCESS_WR / CYCLES
AVG_MEM_READ_REQUEST_RATE = MEM_ACCESS_RD / CYCLES
AVG_MEM_WRITE_REQUEST_RATE = MEM_ACCESS_WR / CYCLES
More details about what other events are available can be found in Tegra410 SoC
technical reference manual.
The events can be filtered based on source or destination. The source filter
indicates the traffic initiator to the SLC, e.g local CPU, non-CPU device, or
remote socket. The destination filter specifies the destination memory type,
e.g. local system memory (CMEM), local GPU memory (GMEM), or remote memory. The
local/remote classification of the destination filter is based on the home
socket of the address, not where the data actually resides. The available
filters are described in
/sys/bus/event_source/devices/nvidia_ucf_pmu_<socket-id>/format/.
The list of UCF PMU event filters:
* Source filter:
* src_loc_cpu: if set, count events from local CPU
* src_loc_noncpu: if set, count events from local non-CPU device
* src_rem: if set, count events from CPU, GPU, PCIE devices of remote socket
* Destination filter:
* dst_loc_cmem: if set, count events to local system memory (CMEM) address
* dst_loc_gmem: if set, count events to local GPU memory (GMEM) address
* dst_loc_other: if set, count events to local CXL memory address
* dst_rem: if set, count events to CPU, GPU, and CXL memory address of remote socket
If the source is not specified, the PMU will count events from all sources. If
the destination is not specified, the PMU will count events to all destinations.
Example usage:
* Count event id 0x0 in socket 0 from all sources and to all destinations::
perf stat -a -e nvidia_ucf_pmu_0/event=0x0/
* Count event id 0x0 in socket 0 with source filter = local CPU and destination
filter = local system memory (CMEM)::
perf stat -a -e nvidia_ucf_pmu_0/event=0x0,src_loc_cpu=0x1,dst_loc_cmem=0x1/
* Count event id 0x0 in socket 1 with source filter = local non-CPU device and
destination filter = remote memory::
perf stat -a -e nvidia_ucf_pmu_1/event=0x0,src_loc_noncpu=0x1,dst_rem=0x1/
PCIE PMU
--------
This PMU is located in the SOC fabric connecting the PCIE root complex (RC) and
the memory subsystem. It monitors all read/write traffic from the root port(s)
or a particular BDF in a PCIE RC to local or remote memory. There is one PMU per
PCIE RC in the SoC. Each RC can have up to 16 lanes that can be bifurcated into
up to 8 root ports. The traffic from each root port can be filtered using RP or
BDF filter. For example, specifying "src_rp_mask=0xFF" means the PMU counter will
capture traffic from all RPs. Please see below for more details.
The events and configuration options of this PMU device are described in sysfs,
see /sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>_rc_<pcie-rc-id>.
The events in this PMU can be used to measure bandwidth, utilization, and
latency:
* rd_req: count the number of read requests by PCIE device.
* wr_req: count the number of write requests by PCIE device.
* rd_bytes: count the number of bytes transferred by rd_req.
* wr_bytes: count the number of bytes transferred by wr_req.
* rd_cum_outs: count outstanding rd_req each cycle.
* cycles: count the clock cycles of SOC fabric connected to the PCIE interface.
The average bandwidth is calculated as::
AVG_RD_BANDWIDTH_IN_GBPS = RD_BYTES / ELAPSED_TIME_IN_NS
AVG_WR_BANDWIDTH_IN_GBPS = WR_BYTES / ELAPSED_TIME_IN_NS
The average request rate is calculated as::
AVG_RD_REQUEST_RATE = RD_REQ / CYCLES
AVG_WR_REQUEST_RATE = WR_REQ / CYCLES
The average latency is calculated as::
FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS
AVG_LATENCY_IN_CYCLES = RD_CUM_OUTS / RD_REQ
AVERAGE_LATENCY_IN_NS = AVG_LATENCY_IN_CYCLES / FREQ_IN_GHZ
The PMU events can be filtered based on the traffic source and destination.
The source filter indicates the PCIE devices that will be monitored. The
destination filter specifies the destination memory type, e.g. local system
memory (CMEM), local GPU memory (GMEM), or remote memory. The local/remote
classification of the destination filter is based on the home socket of the
address, not where the data actually resides. These filters can be found in
/sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>_rc_<pcie-rc-id>/format/.
The list of event filters:
* Source filter:
* src_rp_mask: bitmask of root ports that will be monitored. Each bit in this
bitmask represents the RP index in the RC. If the bit is set, all devices under
the associated RP will be monitored. E.g "src_rp_mask=0xF" will monitor
devices in root port 0 to 3.
* src_bdf: the BDF that will be monitored. This is a 16-bit value that
follows formula: (bus << 8) + (device << 3) + (function). For example, the
value of BDF 27:01.1 is 0x2781.
* src_bdf_en: enable the BDF filter. If this is set, the BDF filter value in
"src_bdf" is used to filter the traffic.
Note that Root-Port and BDF filters are mutually exclusive and the PMU in
each RC can only have one BDF filter for the whole counters. If BDF filter
is enabled, the BDF filter value will be applied to all events.
* Destination filter:
* dst_loc_cmem: if set, count events to local system memory (CMEM) address
* dst_loc_gmem: if set, count events to local GPU memory (GMEM) address
* dst_loc_pcie_p2p: if set, count events to local PCIE peer address
* dst_loc_pcie_cxl: if set, count events to local CXL memory address
* dst_rem: if set, count events to remote memory address
If the source filter is not specified, the PMU will count events from all root
ports. If the destination filter is not specified, the PMU will count events
to all destinations.
Example usage:
* Count event id 0x0 from root port 0 of PCIE RC-0 on socket 0 targeting all
destinations::
perf stat -a -e nvidia_pcie_pmu_0_rc_0/event=0x0,src_rp_mask=0x1/
* Count event id 0x1 from root port 0 and 1 of PCIE RC-1 on socket 0 and
targeting just local CMEM of socket 0::
perf stat -a -e nvidia_pcie_pmu_0_rc_1/event=0x1,src_rp_mask=0x3,dst_loc_cmem=0x1/
* Count event id 0x2 from root port 0 of PCIE RC-2 on socket 1 targeting all
destinations::
perf stat -a -e nvidia_pcie_pmu_1_rc_2/event=0x2,src_rp_mask=0x1/
* Count event id 0x3 from root port 0 and 1 of PCIE RC-3 on socket 1 and
targeting just local CMEM of socket 1::
perf stat -a -e nvidia_pcie_pmu_1_rc_3/event=0x3,src_rp_mask=0x3,dst_loc_cmem=0x1/
* Count event id 0x4 from BDF 01:01.0 of PCIE RC-4 on socket 0 targeting all
destinations::
perf stat -a -e nvidia_pcie_pmu_0_rc_4/event=0x4,src_bdf=0x0180,src_bdf_en=0x1/
.. _NVIDIA_T410_PCIE_PMU_RC_Mapping_Section:
Mapping the RC# to lspci segment number
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Mapping the RC# to lspci segment number can be non-trivial; hence a new NVIDIA
Designated Vendor Specific Capability (DVSEC) register is added into the PCIE config space
for each RP. This DVSEC has vendor id "10de" and DVSEC id of "0x4". The DVSEC register
contains the following information to map PCIE devices under the RP back to its RC# :
- Bus# (byte 0xc) : bus number as reported by the lspci output
- Segment# (byte 0xd) : segment number as reported by the lspci output
- RP# (byte 0xe) : port number as reported by LnkCap attribute from lspci for a device with Root Port capability
- RC# (byte 0xf): root complex number associated with the RP
- Socket# (byte 0x10): socket number associated with the RP
Example script for mapping lspci BDF to RC# and socket#::
#!/bin/bash
while read bdf rest; do
dvsec4_reg=$(lspci -vv -s $bdf | awk '
/Designated Vendor-Specific: Vendor=10de ID=0004/ {
match($0, /\[([0-9a-fA-F]+)/, arr);
print "0x" arr[1];
exit
}
')
if [ -n "$dvsec4_reg" ]; then
bus=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0xc))).b)
segment=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0xd))).b)
rp=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0xe))).b)
rc=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0xf))).b)
socket=$(setpci -s $bdf $(printf '0x%x' $((${dvsec4_reg} + 0x10))).b)
echo "$bdf: Bus=$bus, Segment=$segment, RP=$rp, RC=$rc, Socket=$socket"
fi
done < <(lspci -d 10de:)
Example output::
0001:00:00.0: Bus=00, Segment=01, RP=00, RC=00, Socket=00
0002:80:00.0: Bus=80, Segment=02, RP=01, RC=01, Socket=00
0002:a0:00.0: Bus=a0, Segment=02, RP=02, RC=01, Socket=00
0002:c0:00.0: Bus=c0, Segment=02, RP=03, RC=01, Socket=00
0002:e0:00.0: Bus=e0, Segment=02, RP=04, RC=01, Socket=00
0003:00:00.0: Bus=00, Segment=03, RP=00, RC=02, Socket=00
0004:00:00.0: Bus=00, Segment=04, RP=00, RC=03, Socket=00
0005:00:00.0: Bus=00, Segment=05, RP=00, RC=04, Socket=00
0005:40:00.0: Bus=40, Segment=05, RP=01, RC=04, Socket=00
0005:c0:00.0: Bus=c0, Segment=05, RP=02, RC=04, Socket=00
0006:00:00.0: Bus=00, Segment=06, RP=00, RC=05, Socket=00
0009:00:00.0: Bus=00, Segment=09, RP=00, RC=00, Socket=01
000a:80:00.0: Bus=80, Segment=0a, RP=01, RC=01, Socket=01
000a:a0:00.0: Bus=a0, Segment=0a, RP=02, RC=01, Socket=01
000a:e0:00.0: Bus=e0, Segment=0a, RP=03, RC=01, Socket=01
000b:00:00.0: Bus=00, Segment=0b, RP=00, RC=02, Socket=01
000c:00:00.0: Bus=00, Segment=0c, RP=00, RC=03, Socket=01
000d:00:00.0: Bus=00, Segment=0d, RP=00, RC=04, Socket=01
000d:40:00.0: Bus=40, Segment=0d, RP=01, RC=04, Socket=01
000d:c0:00.0: Bus=c0, Segment=0d, RP=02, RC=04, Socket=01
000e:00:00.0: Bus=00, Segment=0e, RP=00, RC=05, Socket=01
PCIE-TGT PMU
------------
This PMU is located in the SOC fabric connecting the PCIE root complex (RC) and
the memory subsystem. It monitors traffic targeting PCIE BAR and CXL HDM ranges.
There is one PCIE-TGT PMU per PCIE RC in the SoC. Each RC in Tegra410 SoC can
have up to 16 lanes that can be bifurcated into up to 8 root ports (RP). The PMU
provides RP filter to count PCIE BAR traffic to each RP and address filter to
count access to PCIE BAR or CXL HDM ranges. The details of the filters are
described in the following sections.
Mapping the RC# to lspci segment number is similar to the PCIE PMU. Please see
:ref:`NVIDIA_T410_PCIE_PMU_RC_Mapping_Section` for more info.
The events and configuration options of this PMU device are available in sysfs,
see /sys/bus/event_source/devices/nvidia_pcie_tgt_pmu_<socket-id>_rc_<pcie-rc-id>.
The events in this PMU can be used to measure bandwidth and utilization:
* rd_req: count the number of read requests to PCIE.
* wr_req: count the number of write requests to PCIE.
* rd_bytes: count the number of bytes transferred by rd_req.
* wr_bytes: count the number of bytes transferred by wr_req.
* cycles: count the clock cycles of SOC fabric connected to the PCIE interface.
The average bandwidth is calculated as::
AVG_RD_BANDWIDTH_IN_GBPS = RD_BYTES / ELAPSED_TIME_IN_NS
AVG_WR_BANDWIDTH_IN_GBPS = WR_BYTES / ELAPSED_TIME_IN_NS
The average request rate is calculated as::
AVG_RD_REQUEST_RATE = RD_REQ / CYCLES
AVG_WR_REQUEST_RATE = WR_REQ / CYCLES
The PMU events can be filtered based on the destination root port or target
address range. Filtering based on RP is only available for PCIE BAR traffic.
Address filter works for both PCIE BAR and CXL HDM ranges. These filters can be
found in sysfs, see
/sys/bus/event_source/devices/nvidia_pcie_tgt_pmu_<socket-id>_rc_<pcie-rc-id>/format/.
Destination filter settings:
* dst_rp_mask: bitmask to select the root port(s) to monitor. E.g. "dst_rp_mask=0xFF"
corresponds to all root ports (from 0 to 7) in the PCIE RC. Note that this filter is
only available for PCIE BAR traffic.
* dst_addr_base: BAR or CXL HDM filter base address.
* dst_addr_mask: BAR or CXL HDM filter address mask.
* dst_addr_en: enable BAR or CXL HDM address range filter. If this is set, the
address range specified by "dst_addr_base" and "dst_addr_mask" will be used to filter
the PCIE BAR and CXL HDM traffic address. The PMU uses the following comparison
to determine if the traffic destination address falls within the filter range::
(txn's addr & dst_addr_mask) == (dst_addr_base & dst_addr_mask)
If the comparison succeeds, then the event will be counted.
If the destination filter is not specified, the RP filter will be configured by default
to count PCIE BAR traffic to all root ports.
Example usage:
* Count event id 0x0 to root port 0 and 1 of PCIE RC-0 on socket 0::
perf stat -a -e nvidia_pcie_tgt_pmu_0_rc_0/event=0x0,dst_rp_mask=0x3/
* Count event id 0x1 for accesses to PCIE BAR or CXL HDM address range
0x10000 to 0x100FF on socket 0's PCIE RC-1::
perf stat -a -e nvidia_pcie_tgt_pmu_0_rc_1/event=0x1,dst_addr_base=0x10000,dst_addr_mask=0xFFF00,dst_addr_en=0x1/
CPU Memory (CMEM) Latency PMU
-----------------------------
This PMU monitors latency events of memory read requests from the edge of the
Unified Coherence Fabric (UCF) to local CPU DRAM:
* RD_REQ counters: count read requests (32B per request).
* RD_CUM_OUTS counters: accumulated outstanding request counter, which track
how many cycles the read requests are in flight.
* CYCLES counter: counts the number of elapsed cycles.
The average latency is calculated as::
FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS
AVG_LATENCY_IN_CYCLES = RD_CUM_OUTS / RD_REQ
AVERAGE_LATENCY_IN_NS = AVG_LATENCY_IN_CYCLES / FREQ_IN_GHZ
The events and configuration options of this PMU device are described in sysfs,
see /sys/bus/event_source/devices/nvidia_cmem_latency_pmu_<socket-id>.
Example usage::
perf stat -a -e '{nvidia_cmem_latency_pmu_0/rd_req/,nvidia_cmem_latency_pmu_0/rd_cum_outs/,nvidia_cmem_latency_pmu_0/cycles/}'
NVLink-C2C PMU
--------------
This PMU monitors latency events of memory read/write requests that pass through
the NVIDIA Chip-to-Chip (C2C) interface. Bandwidth events are not available
in this PMU, unlike the C2C PMU in Grace (Tegra241 SoC).
The events and configuration options of this PMU device are available in sysfs,
see /sys/bus/event_source/devices/nvidia_nvlink_c2c_pmu_<socket-id>.
The list of events:
* IN_RD_CUM_OUTS: accumulated outstanding request (in cycles) of incoming read requests.
* IN_RD_REQ: the number of incoming read requests.
* IN_WR_CUM_OUTS: accumulated outstanding request (in cycles) of incoming write requests.
* IN_WR_REQ: the number of incoming write requests.
* OUT_RD_CUM_OUTS: accumulated outstanding request (in cycles) of outgoing read requests.
* OUT_RD_REQ: the number of outgoing read requests.
* OUT_WR_CUM_OUTS: accumulated outstanding request (in cycles) of outgoing write requests.
* OUT_WR_REQ: the number of outgoing write requests.
* CYCLES: NVLink-C2C interface cycle counts.
The incoming events count the reads/writes from remote device to the SoC.
The outgoing events count the reads/writes from the SoC to remote device.
The sysfs /sys/bus/event_source/devices/nvidia_nvlink_c2c_pmu_<socket-id>/peer
contains the information about the connected device.
When the C2C interface is connected to GPU(s), the user can use the
"gpu_mask" parameter to filter traffic to/from specific GPU(s). Each bit represents the GPU
index, e.g. "gpu_mask=0x1" corresponds to GPU 0 and "gpu_mask=0x3" is for GPU 0 and 1.
The PMU will monitor all GPUs by default if not specified.
When connected to another SoC, only the read events are available.
The events can be used to calculate the average latency of the read/write requests::
C2C_FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS
IN_RD_AVG_LATENCY_IN_CYCLES = IN_RD_CUM_OUTS / IN_RD_REQ
IN_RD_AVG_LATENCY_IN_NS = IN_RD_AVG_LATENCY_IN_CYCLES / C2C_FREQ_IN_GHZ
IN_WR_AVG_LATENCY_IN_CYCLES = IN_WR_CUM_OUTS / IN_WR_REQ
IN_WR_AVG_LATENCY_IN_NS = IN_WR_AVG_LATENCY_IN_CYCLES / C2C_FREQ_IN_GHZ
OUT_RD_AVG_LATENCY_IN_CYCLES = OUT_RD_CUM_OUTS / OUT_RD_REQ
OUT_RD_AVG_LATENCY_IN_NS = OUT_RD_AVG_LATENCY_IN_CYCLES / C2C_FREQ_IN_GHZ
OUT_WR_AVG_LATENCY_IN_CYCLES = OUT_WR_CUM_OUTS / OUT_WR_REQ
OUT_WR_AVG_LATENCY_IN_NS = OUT_WR_AVG_LATENCY_IN_CYCLES / C2C_FREQ_IN_GHZ
Example usage:
* Count incoming traffic from all GPUs connected via NVLink-C2C::
perf stat -a -e nvidia_nvlink_c2c_pmu_0/in_rd_req/
* Count incoming traffic from GPU 0 connected via NVLink-C2C::
perf stat -a -e nvidia_nvlink_c2c_pmu_0/in_rd_cum_outs,gpu_mask=0x1/
* Count incoming traffic from GPU 1 connected via NVLink-C2C::
perf stat -a -e nvidia_nvlink_c2c_pmu_0/in_rd_cum_outs,gpu_mask=0x2/
* Count outgoing traffic to all GPUs connected via NVLink-C2C::
perf stat -a -e nvidia_nvlink_c2c_pmu_0/out_rd_req/
* Count outgoing traffic to GPU 0 connected via NVLink-C2C::
perf stat -a -e nvidia_nvlink_c2c_pmu_0/out_rd_cum_outs,gpu_mask=0x1/
* Count outgoing traffic to GPU 1 connected via NVLink-C2C::
perf stat -a -e nvidia_nvlink_c2c_pmu_0/out_rd_cum_outs,gpu_mask=0x2/
NV-CLink PMU
------------
This PMU monitors latency events of memory read requests that pass through
the NV-CLINK interface. Bandwidth events are not available in this PMU.
In Tegra410 SoC, the NV-CLink interface is used to connect to another Tegra410
SoC and this PMU only counts read traffic.
The events and configuration options of this PMU device are available in sysfs,
see /sys/bus/event_source/devices/nvidia_nvclink_pmu_<socket-id>.
The list of events:
* IN_RD_CUM_OUTS: accumulated outstanding request (in cycles) of incoming read requests.
* IN_RD_REQ: the number of incoming read requests.
* OUT_RD_CUM_OUTS: accumulated outstanding request (in cycles) of outgoing read requests.
* OUT_RD_REQ: the number of outgoing read requests.
* CYCLES: NV-CLINK interface cycle counts.
The incoming events count the reads from remote device to the SoC.
The outgoing events count the reads from the SoC to remote device.
The events can be used to calculate the average latency of the read requests::
CLINK_FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS
IN_RD_AVG_LATENCY_IN_CYCLES = IN_RD_CUM_OUTS / IN_RD_REQ
IN_RD_AVG_LATENCY_IN_NS = IN_RD_AVG_LATENCY_IN_CYCLES / CLINK_FREQ_IN_GHZ
OUT_RD_AVG_LATENCY_IN_CYCLES = OUT_RD_CUM_OUTS / OUT_RD_REQ
OUT_RD_AVG_LATENCY_IN_NS = OUT_RD_AVG_LATENCY_IN_CYCLES / CLINK_FREQ_IN_GHZ
Example usage:
* Count incoming read traffic from remote SoC connected via NV-CLINK::
perf stat -a -e nvidia_nvclink_pmu_0/in_rd_req/
* Count outgoing read traffic to remote SoC connected via NV-CLINK::
perf stat -a -e nvidia_nvclink_pmu_0/out_rd_req/
NV-DLink PMU
------------
This PMU monitors latency events of memory read requests that pass through
the NV-DLINK interface. Bandwidth events are not available in this PMU.
In Tegra410 SoC, this PMU only counts CXL memory read traffic.
The events and configuration options of this PMU device are available in sysfs,
see /sys/bus/event_source/devices/nvidia_nvdlink_pmu_<socket-id>.
The list of events:
* IN_RD_CUM_OUTS: accumulated outstanding read requests (in cycles) to CXL memory.
* IN_RD_REQ: the number of read requests to CXL memory.
* CYCLES: NV-DLINK interface cycle counts.
The events can be used to calculate the average latency of the read requests::
DLINK_FREQ_IN_GHZ = CYCLES / ELAPSED_TIME_IN_NS
IN_RD_AVG_LATENCY_IN_CYCLES = IN_RD_CUM_OUTS / IN_RD_REQ
IN_RD_AVG_LATENCY_IN_NS = IN_RD_AVG_LATENCY_IN_CYCLES / DLINK_FREQ_IN_GHZ
Example usage:
* Count read events to CXL memory::
perf stat -a -e '{nvidia_nvdlink_pmu_0/in_rd_req/,nvidia_nvdlink_pmu_0/in_rd_cum_outs/}'
@@ -0,0 +1,39 @@
=====================================================================
Qualcomm Technologies Level-2 Cache Performance Monitoring Unit (PMU)
=====================================================================
This driver supports the L2 cache clusters found in Qualcomm Technologies
Centriq SoCs. There are multiple physical L2 cache clusters, each with their
own PMU. Each cluster has one or more CPUs associated with it.
There is one logical L2 PMU exposed, which aggregates the results from
the physical PMUs.
The driver provides a description of its available events and configuration
options in sysfs, see /sys/bus/event_source/devices/l2cache_0.
The "format" directory describes the format of the events.
Events can be envisioned as a 2-dimensional array. Each column represents
a group of events. There are 8 groups. Only one entry from each
group can be in use at a time. If multiple events from the same group
are specified, the conflicting events cannot be counted at the same time.
Events are specified as 0xCCG, where CC is 2 hex digits specifying
the code (array row) and G specifies the group (column) 0-7.
In addition there is a cycle counter event specified by the value 0xFE
which is outside the above scheme.
The driver provides a "cpumask" sysfs attribute which contains a mask
consisting of one CPU per cluster which will be used to handle all the PMU
events on that cluster.
Examples for use with perf::
perf stat -e l2cache_0/config=0x001/,l2cache_0/config=0x042/ -a sleep 1
perf stat -e l2cache_0/config=0xfe/ -C 2 sleep 1
The driver does not support sampling, therefore "perf record" will
not work. Per-task perf sessions are not supported.
@@ -0,0 +1,26 @@
===========================================================================
Qualcomm Datacenter Technologies L3 Cache Performance Monitoring Unit (PMU)
===========================================================================
This driver supports the L3 cache PMUs found in Qualcomm Datacenter Technologies
Centriq SoCs. The L3 cache on these SOCs is composed of multiple slices, shared
by all cores within a socket. Each slice is exposed as a separate uncore perf
PMU with device name l3cache_<socket>_<instance>. User space is responsible
for aggregating across slices.
The driver provides a description of its available events and configuration
options in sysfs, see /sys/bus/event_source/devices/l3cache*. Given that these are uncore PMUs
the driver also exposes a "cpumask" sysfs attribute which contains a mask
consisting of one CPU per socket which will be used to handle all the PMU
events on that socket.
The hardware implements 32bit event counters and has a flat 8bit event space
exposed via the "event" format attribute. In addition to the 32bit physical
counters the driver supports virtual 64bit hardware counters by using hardware
counter chaining. This feature is exposed via the "lc" (long counter) format
flag. E.g.::
perf stat -e l3cache_0_0/read-miss,lc/
Given that these are uncore PMUs the driver does not support sampling, therefore
"perf record" will not work. Per-task perf sessions are not supported.
@@ -0,0 +1,46 @@
================================================
StarFive StarLink Performance Monitor Unit (PMU)
================================================
StarFive StarLink Performance Monitor Unit (PMU) exists within the
StarLink Coherent Network on Chip (CNoC) that connects multiple CPU
clusters with an L3 memory system.
The uncore PMU supports overflow interrupt, up to 16 programmable 64bit
event counters, and an independent 64bit cycle counter.
The PMU can only be accessed via Memory Mapped I/O and are common to the
cores connected to the same PMU.
Driver exposes supported PMU events in sysfs "events" directory under::
/sys/bus/event_source/devices/starfive_starlink_pmu/events/
Driver exposes cpu used to handle PMU events in sysfs "cpumask" directory
under::
/sys/bus/event_source/devices/starfive_starlink_pmu/cpumask/
Driver describes the format of config (event ID) in sysfs "format" directory
under::
/sys/bus/event_source/devices/starfive_starlink_pmu/format/
Example of perf usage::
$ perf list
starfive_starlink_pmu/cycles/ [Kernel PMU event]
starfive_starlink_pmu/read_hit/ [Kernel PMU event]
starfive_starlink_pmu/read_miss/ [Kernel PMU event]
starfive_starlink_pmu/read_request/ [Kernel PMU event]
starfive_starlink_pmu/release_request/ [Kernel PMU event]
starfive_starlink_pmu/write_hit/ [Kernel PMU event]
starfive_starlink_pmu/write_miss/ [Kernel PMU event]
starfive_starlink_pmu/write_request/ [Kernel PMU event]
starfive_starlink_pmu/writeback/ [Kernel PMU event]
$ perf stat -a -e /starfive_starlink_pmu/cycles/ sleep 1
Sampling is not supported. As a result, "perf record" is not supported.
Attaching to a task is not supported, only system-wide counting is supported.
@@ -0,0 +1,44 @@
=============================================================
Cavium ThunderX2 SoC Performance Monitoring Unit (PMU UNCORE)
=============================================================
The ThunderX2 SoC PMU consists of independent, system-wide, per-socket
PMUs such as the Level 3 Cache (L3C), DDR4 Memory Controller (DMC) and
Cavium Coherent Processor Interconnect (CCPI2).
The DMC has 8 interleaved channels and the L3C has 16 interleaved tiles.
Events are counted for the default channel (i.e. channel 0) and prorated
to the total number of channels/tiles.
The DMC and L3C support up to 4 counters, while the CCPI2 supports up to 8
counters. Counters are independently programmable to different events and
can be started and stopped individually. None of the counters support an
overflow interrupt. DMC and L3C counters are 32-bit and read every 2 seconds.
The CCPI2 counters are 64-bit and assumed not to overflow in normal operation.
PMU UNCORE (perf) driver:
The thunderx2_pmu driver registers per-socket perf PMUs for the DMC and
L3C devices. Each PMU can be used to count up to 4 (DMC/L3C) or up to 8
(CCPI2) events simultaneously. The PMUs provide a description of their
available events and configuration options under sysfs, see
/sys/bus/event_source/devices/uncore_<l3c_S/dmc_S/ccpi2_S/>; S is the socket id.
The driver does not support sampling, therefore "perf record" will not
work. Per-task perf sessions are also not supported.
Examples::
# perf stat -a -e uncore_dmc_0/cnt_cycles/ sleep 1
# perf stat -a -e \
uncore_dmc_0/cnt_cycles/,\
uncore_dmc_0/data_transfers/,\
uncore_dmc_0/read_txns/,\
uncore_dmc_0/write_txns/ sleep 1
# perf stat -a -e \
uncore_l3c_0/read_request/,\
uncore_l3c_0/read_hit/,\
uncore_l3c_0/inv_request/,\
uncore_l3c_0/inv_hit/ sleep 1
@@ -0,0 +1,49 @@
================================================
APM X-Gene SoC Performance Monitoring Unit (PMU)
================================================
X-Gene SoC PMU consists of various independent system device PMUs such as
L3 cache(s), I/O bridge(s), memory controller bridge(s) and memory
controller(s). These PMU devices are loosely architected to follow the
same model as the PMU for ARM cores. The PMUs share the same top level
interrupt and status CSR region.
PMU (perf) driver
-----------------
The xgene-pmu driver registers several perf PMU drivers. Each of the perf
driver provides description of its available events and configuration options
in sysfs, see /sys/bus/event_source/devices/<l3cX/iobX/mcbX/mcX>/.
The "format" directory describes format of the config (event ID),
config1 (agent ID) fields of the perf_event_attr structure. The "events"
directory provides configuration templates for all supported event types that
can be used with perf tool. For example, "l3c0/bank-fifo-full/" is an
equivalent of "l3c0/config=0x0b/".
Most of the SoC PMU has a specific list of agent ID used for monitoring
performance of a specific datapath. For example, agents of a L3 cache can be
a specific CPU or an I/O bridge. Each PMU has a set of 2 registers capable of
masking the agents from which the request come from. If the bit with
the bit number corresponding to the agent is set, the event is counted only if
it is caused by a request from that agent. Each agent ID bit is inversely mapped
to a corresponding bit in "config1" field. By default, the event will be
counted for all agent requests (config1 = 0x0). For all the supported agents of
each PMU, please refer to APM X-Gene User Manual.
Each perf driver also provides a "cpumask" sysfs attribute, which contains a
single CPU ID of the processor which will be used to handle all the PMU events.
Example for perf tool use::
/ # perf list | grep -e l3c -e iob -e mcb -e mc
l3c0/ackq-full/ [Kernel PMU event]
<...>
mcb1/mcb-csw-stall/ [Kernel PMU event]
/ # perf stat -a -e l3c0/read-miss/,mcb1/csw-write-request/ sleep 1
/ # perf stat -a -e l3c0/read-miss,config1=0xfffffffffffffffe/ sleep 1
The driver does not support sampling, therefore "perf record" will