Kernel driver adt7411
|
|
=====================
|
|
|
|
Supported chips:
|
|
|
|
* Analog Devices ADT7411
|
|
|
|
Prefix: 'adt7411'
|
|
|
|
Addresses scanned: 0x48, 0x4a, 0x4b
|
|
|
|
Datasheet: Publicly available at the Analog Devices website
|
|
|
|
Author: Wolfram Sang (based on adt7470 by Darrick J. Wong)
|
|
|
|
Description
|
|
-----------
|
|
|
|
This driver implements support for the Analog Devices ADT7411 chip. There may
|
|
be other chips that implement this interface.
|
|
|
|
The ADT7411 can use an I2C/SMBus compatible 2-wire interface or an
|
|
SPI-compatible 4-wire interface. It provides a 10-bit analog to digital
|
|
converter which measures 1 temperature, vdd and 8 input voltages. It has an
|
|
internal temperature sensor, but an external one can also be connected (one
|
|
loses 2 inputs then). There are high- and low-limit registers for all inputs.
|
|
|
|
Check the datasheet for details.
|
|
|
|
sysfs-Interface
|
|
---------------
|
|
|
|
================ =================================
|
|
in0_input vdd voltage input
|
|
in0_min vdd low limit
|
|
in0_max vdd high limit
|
|
in0_alarm vdd alarm
|
|
in[1-8]_input analog 1-8 input
|
|
in[1-8]_min analog input low limit
|
|
in[1-8]_max analog input high limit
|
|
in[1-8]_alarm analog input alarm
|
|
temp1_input internal temperature input
|
|
temp1_min internal temperature low limit
|
|
temp1_max internal temperature high limit
|
|
temp1_min_alarm internal temperature low alarm
|
|
temp1_max_alarm internal temperature high alarm
|
|
================ =================================
|
|
|
|
If the external temperature sensor is enabled, the following attributes are
|
|
also available:
|
|
|
|
================ ================================================
|
|
temp2_input external temperature input
|
|
temp2_min external temperature low limit
|
|
temp2_max external temperature high limit
|
|
temp2_min_alarm external temperature low alarm
|
|
temp2_max_alarm external temperature high alarm
|
|
temp2_fault external temperature sensor fault
|
|
================ ================================================
|
|
|
|
If the external temperature sensor is enabled, analog inputs in1 and in2 are
|
|
not available.
|
|
|
|
Besides standard interfaces, this driver adds (0 = off, 1 = on):
|
|
|
|
============== =======================================================
|
|
adc_ref_vdd Use vdd as reference instead of 2.25 V
|
|
fast_sampling Sample at 22.5 kHz instead of 1.4 kHz, but drop filters
|
|
no_average Turn off averaging over 16 samples
|
|
============== =======================================================
|
|
|
|
Notes
|
|
-----
|
|
|
|
SPI is not supported yet.
|